17
REGULATION AND TRANSFORMATION OPERATIONS
10) REPLACING NOZZLES
The burners can be adapted to suited different
types of gas by fitting the nozzles that correspond
to the gas used. To do this, it is necessary to
remove the burner heads and use a straight key
“B”, to unscrew the nozzle “A” (see fig. 13) and
replace it with a nozzle corresponding to the gas
used.
We advise you to block the nozzle tightly.
After making
these replacements,
the
technician must regulate the burners as
described in paragraph 9, seal any regulation
or pre-regulation organs and apply the label
corresponding to the new gas regulation
carried out on the appliance in place of that
previously applied. This label is contained in
the spare nozzle bag.
For the ease of the fitter, we have prepared a table
indicating the flow capacities, the heat capacities
of the burners, the diameter of the nozzles and the
working pressure for the various types of gas.
ARRANGEMENT OF THE BURNERS
TABLE
78 cm.
86 cm.
FIG. 13
BURNERS
GAS
WORKING
PRESSURE
mbar
HEAT
CAPACITY
NOZZLE
DIAMETER
1/100 mm
HEAT
CAPACITY (W)
No.
DESCRIPTION
g/h
l/h
Min.
Max.
2
TIPLE RING
G30 - BUTANE
G31 - PROPANE
G20 - NATURAL
28 - 30
37
20
276
271
357
100 B
100 B
145 A
1800
1800
1800
3800
3800
3750
3
DUAL
total
G30 - BUTANE
G31 - PROPANE
G20 - NATURAL
28 - 30
37
20
345
339
476
2 x 69A + 46 B
2 x 69A + 46 B
2 x 110 A + 71 A
1800
1800
1800
4200
4200
4200
DUAL
central
G30 - BUTANE
G31 - PROPANE
G20 - NATURAL
28 - 30
37
20
65
64
86
46 B
46 B
71 A
450
450
450
900
900
900
4
AUXILIARY
G30 - BUTANE
G31 - PROPANE
G20 - NATURAL
28 - 30
37
20
73
71
95
50
50
72 X
450
450
450
1000
1000
1000