DUDOFF G02-Z3 Installation And User Instructions Manual Download Page 15

15

INSTALLATION

8) ELECTRICAL CONNECTION

The electrical connection must be made in
compliance  with  the  standards  and  legal
provisions in force.

Before making the connection, ensure that:
- the voltage matches the value shown on the

specification plate and the section of the wires of
the electrical system can support the load, which
is also indicated on the specification plate.

- The socket or system has an effective earth

connection in compliance with the standards and
legal provisions currently in force. We cannot
accept any responsibility for failure to observe
these provisions.

When the appliance is connected to the power
supply via socket:

- fit a standard plug suited to the load indicated on

the label to the power cable “C” if necessary. 

- Connect the wires in compliance with the diagram

in fig. 11, ensuring that the following are observed:

letter L (phase) = brown wire; 

letter N (neutral) = blue wire;

earth symbol 

= green-yellow wire.

- The power cable must be positioned so that it

does not reach an temperature of 90 °C in any
point.

- Do not use reductions, adapters or shunts for the

connection, as they could make false contacts
causing hazards due to overheating.

- The socket must be accessible after fitting.

When the connection is made directly to the
electricity main:

- insert an omnipolar switch between the appliance

and the power network, in a size suited to the load
of the appliance, with a minimum aperture
between contacts of 3 mm. 

- Remember that the earth cable must not be

interrupted by the switch.

- The electrical connection may also be protected

with a highly sensitive differential switch.

We strongly recommend that you connect the
appropriate green-yellow earth wire to an efficient
earth system.

Before performing any service on the electrical
part of the appliance, it must absolutely be
disconnected from the electrical network.

The manufacturer declines all responsibility for
damages suffered by people and items due to
failure to observe the aforementioned indications,
or deriving from interference with a single part of
the appliance.

WARNINGS: 
all our products are conform with the 
European Norms and relative amendments.  
The product is therefore conform with the 
requirements of the European Directivesin 
force relating to: 
- compatibility electromagnetic (EMC); 
- electrical security (LVD); 
- restriction of use of certain hazardous

substances (RoHS); 

- EcoDesign (ERP).

IMPORTANT!
The appliance must be installed following
the manufacturer's instructions. The
manufacturer will not be liable for injury
to  persons  or  animals  or  property
damage 

caused 

by  an  incorrect

installation.

If the installation requires modifications
to the home's electrical system or if the
socket 

is  incompatible 

with 

the

appliance's  plug,  have  changes  or
replacements 

performed 

by

professionally-qualified 

person. 

In

particular, this person must also make
sure that the section of the wires of the
socket is suitable for the power absorbed
by the appliance.

FIG. 11

Summary of Contents for G02-Z3

Page 1: ...INSTALLATION AND USER INSTRUCTIONS BUILT IN GAS HOB TOUCH CONTROL...

Page 2: ...for domestic use in domestic environments by members of the general public It must be used by fully aware adults Children should not be allowed to approach or play with the appliance The easy to reac...

Page 3: ...vels display 0 9 11 Display clock DESCRIPTION OF THE FRONT PANEL CONTROLS 3F of 78 86 cm 2F of 78 86 cm DUAL 1 Burner 3 button crown internal and external 2 Burner 3 button crown internal and external...

Page 4: ...e the capacity to the minimum level for every burner for fitter only Programming the type of fuel used methane lpg for fitter only Programming of the switch off time for every burner Maximum duration...

Page 5: ...is sufficient to keep the or button pressed and release it at the level required The capacity level varies from 1 to 9 5 USE The Dual burner instead can be lit partially internal ring or completely i...

Page 6: ...elected together A time equal to zero deactivates the burner timer To confirm the time shown on the display press the Clock button 7 At this point only the indicators of the burners with the timer act...

Page 7: ...evels will remain stable The control panel locked status occurs when the decimal points on the display of the capacity level related to each burner light up While the control panel is locked it is no...

Page 8: ...physical capacities or without experience of using electrical devices unless supervised or instructed by an expert adult responsible for their care and safety Children should not be allowed to play wi...

Page 9: ...osing of it make it inoperative in conformity with current law on the protection of health and the prevention of environmental pollution by making its dangerous parts harmless especially for children...

Page 10: ...d flame detection TC see fig 4 Clean them gently with a small nylon brush as shown see fig 6 and allow to dry fully Do not wash in the dishwasher It is very important to clean the surface soon after e...

Page 11: ...te the warranty Observe the national and European standards applicable e g EN 60335 1 EN 50165 in relation to electrical safety Before entry into operation check the wiring carefully incorrect wiring...

Page 12: ...ent have to permit the easy loading and unloading of the cylinder For an efficient aeration is necessary to make some small openings in the furniture as per fig 9 A and 9 B The cylinder holder compart...

Page 13: ...and surrounding the hob must resist an temperature of 90 C The glue which joins the plastic laminate to the unit must be able to resist temperatures of at least 150 C to prevent the coating from beco...

Page 14: ...egulator compliant with the standards in force must be connected with copper piping compliant with the standards in force the joints of which must be made using mechanical seal fittings compliant with...

Page 15: ...the appliance with a minimum aperture between contacts of 3 mm Remember that the earth cable must not be interrupted by the switch The electrical connection may also be protected with a highly sensiti...

Page 16: ...city than that programmed To confirm the minimum capacity required it is necessary to press the Clock button 7 The word MIN will continue to be present and none of the leds will flash At this point it...

Page 17: ...ontained in the spare nozzle bag For the ease of the fitter we have prepared a table indicating the flow capacities the heat capacities of the burners the diameter of the nozzles and the working press...

Page 18: ...wiring and then restore the power supply Driving anomaly on valve B Valve B incorrect wiring Cut off the power supply check valve B wiring and then restore the power supply Driving anomaly on valve C...

Page 19: ...19 REGULATION AND TRANSFORMATION OPERATIONS MEASUREMENTS electronic card...

Page 20: ...rea of the control panel before switching on After switching on the hob wait a few seconds to complete the automatic calibration procedure of the control panel In the event of a partial short circuit...

Page 21: ...ase conductor fig 19 and must also observe the warnings indicated in paragraph 8 Gas hob H05 RR F Section 3 x 0 75 mm 2 WARNING MAINTENANCE MUST ONLY BE PERFORMED BY AUTHORISED PERSONS In case of fail...

Page 22: ...d into the device for regulating the minimum level for each burner Power supply card created using switching technology Daily clock in 24h format TECHNICAL DATA Power supply 100 240V a c 10 Frequency...

Page 23: ...E Gas G30 8 0 kW Qn BUTANE Gas 582 g h G30 571 g h G31 Voltage 220 240 V Frequency 50 60 Hz 3 BURNERS 86 2 Triple Ring 1 AUXILIARY G30 BUTANE 28 30 mbar G31 PROPANE 37 mbar G20 NATURAL 20 mbar Qn Natu...

Page 24: ...entre specifying the brand the model the serial number and the type of problem affecting your appliance The pertinent data is stamped on the label applied to the underside of the appliance and on the...

Reviews: