DUDOFF G02-Z3 Installation And User Instructions Manual Download Page 11

11

INSTALLATION

FIG. 7

FIG. 8

MEASUREMENTS TO OBSERVE (in mm)

TECHNICAL INFORMATION 

FOR FITTERS

Installation 

and 

all 

the 

regulation,

transformation and maintenance operations
listed in this section must be carried out
exclusively by qualified personnel.
The appliance must be correctly installed in
conformity 

with 

current 

law  and  the

manufacturer's instructions.
Incorrect installation may cause injury to people
or animals, or damage to items, for which the
manufacturer cannot be held responsible.
Throughout the life of the system, the devices
for the safety and automatic regulation of the
appliances  must  only  be  modified  by  the
manufacturer or the duly authorised supplier.

INDICATIONS FOR INSTALLATION

●The device is designed to remain operational for

less than 24 h (non-permanent operating system).
When this limit is reached, a regulation stoppage
occurs so the device can check its efficiency.

●This automatic device is a safety device and must

not be altered. Interference with this device will
eliminate any responsibility by the manufacturer
and invalidate the warranty.

●Observe the national and European standards

applicable (e.g., EN 60335-1/EN 50165)  in
relation to electrical safety.

●Before entry into operation, check the wiring

carefully: incorrect wiring may damage the device
and jeopardise the safety of the system.

●Connect and disconnect the hob only after cutting

off the electricity supply.

●Avoid exposing the device to drops of water.
●Avoid laying the valve wires along with the high

voltage wires of the ignition transformer.

●Ensure  that  there  is  nothing  on  the  hob,

particularly on the area of the control panel, before
switching on.

●After switching on the hob, wait a few seconds to

complete the automatic calibration procedure of
the control panel.  

●In the event of a “partial” short circuit or insufficient

insulation between the line and earth, the voltage
on the sensor electrode may be reduced so much
that it causes the device to lock, due to the
impossibility to sense the flame signal.

●The extra low voltage (ELV) circuit is not safe to

touch (only main insulation in compliance with 

EN 60730-1), so the installation must guarantee

the level of protection against electric shock
equivalent to double insulation for the user
interface.

A

B

C

D

E

2F - 3F (78)

705

405

95

95

97.5 min.

2F - 3F (86)

705

405

95

95

97.5 min.

Summary of Contents for G02-Z3

Page 1: ...INSTALLATION AND USER INSTRUCTIONS BUILT IN GAS HOB TOUCH CONTROL...

Page 2: ...for domestic use in domestic environments by members of the general public It must be used by fully aware adults Children should not be allowed to approach or play with the appliance The easy to reac...

Page 3: ...vels display 0 9 11 Display clock DESCRIPTION OF THE FRONT PANEL CONTROLS 3F of 78 86 cm 2F of 78 86 cm DUAL 1 Burner 3 button crown internal and external 2 Burner 3 button crown internal and external...

Page 4: ...e the capacity to the minimum level for every burner for fitter only Programming the type of fuel used methane lpg for fitter only Programming of the switch off time for every burner Maximum duration...

Page 5: ...is sufficient to keep the or button pressed and release it at the level required The capacity level varies from 1 to 9 5 USE The Dual burner instead can be lit partially internal ring or completely i...

Page 6: ...elected together A time equal to zero deactivates the burner timer To confirm the time shown on the display press the Clock button 7 At this point only the indicators of the burners with the timer act...

Page 7: ...evels will remain stable The control panel locked status occurs when the decimal points on the display of the capacity level related to each burner light up While the control panel is locked it is no...

Page 8: ...physical capacities or without experience of using electrical devices unless supervised or instructed by an expert adult responsible for their care and safety Children should not be allowed to play wi...

Page 9: ...osing of it make it inoperative in conformity with current law on the protection of health and the prevention of environmental pollution by making its dangerous parts harmless especially for children...

Page 10: ...d flame detection TC see fig 4 Clean them gently with a small nylon brush as shown see fig 6 and allow to dry fully Do not wash in the dishwasher It is very important to clean the surface soon after e...

Page 11: ...te the warranty Observe the national and European standards applicable e g EN 60335 1 EN 50165 in relation to electrical safety Before entry into operation check the wiring carefully incorrect wiring...

Page 12: ...ent have to permit the easy loading and unloading of the cylinder For an efficient aeration is necessary to make some small openings in the furniture as per fig 9 A and 9 B The cylinder holder compart...

Page 13: ...and surrounding the hob must resist an temperature of 90 C The glue which joins the plastic laminate to the unit must be able to resist temperatures of at least 150 C to prevent the coating from beco...

Page 14: ...egulator compliant with the standards in force must be connected with copper piping compliant with the standards in force the joints of which must be made using mechanical seal fittings compliant with...

Page 15: ...the appliance with a minimum aperture between contacts of 3 mm Remember that the earth cable must not be interrupted by the switch The electrical connection may also be protected with a highly sensiti...

Page 16: ...city than that programmed To confirm the minimum capacity required it is necessary to press the Clock button 7 The word MIN will continue to be present and none of the leds will flash At this point it...

Page 17: ...ontained in the spare nozzle bag For the ease of the fitter we have prepared a table indicating the flow capacities the heat capacities of the burners the diameter of the nozzles and the working press...

Page 18: ...wiring and then restore the power supply Driving anomaly on valve B Valve B incorrect wiring Cut off the power supply check valve B wiring and then restore the power supply Driving anomaly on valve C...

Page 19: ...19 REGULATION AND TRANSFORMATION OPERATIONS MEASUREMENTS electronic card...

Page 20: ...rea of the control panel before switching on After switching on the hob wait a few seconds to complete the automatic calibration procedure of the control panel In the event of a partial short circuit...

Page 21: ...ase conductor fig 19 and must also observe the warnings indicated in paragraph 8 Gas hob H05 RR F Section 3 x 0 75 mm 2 WARNING MAINTENANCE MUST ONLY BE PERFORMED BY AUTHORISED PERSONS In case of fail...

Page 22: ...d into the device for regulating the minimum level for each burner Power supply card created using switching technology Daily clock in 24h format TECHNICAL DATA Power supply 100 240V a c 10 Frequency...

Page 23: ...E Gas G30 8 0 kW Qn BUTANE Gas 582 g h G30 571 g h G31 Voltage 220 240 V Frequency 50 60 Hz 3 BURNERS 86 2 Triple Ring 1 AUXILIARY G30 BUTANE 28 30 mbar G31 PROPANE 37 mbar G20 NATURAL 20 mbar Qn Natu...

Page 24: ...entre specifying the brand the model the serial number and the type of problem affecting your appliance The pertinent data is stamped on the label applied to the underside of the appliance and on the...