Installation Manual for DualSun PV Modules
8.2
Module appearance inspection
Check module appearance defects visually, especially:
1. Module glass cracks.
2. Corrosion at welding parts of the cell main grid: it is caused by moisture into the module due
to damage of surface packaging materials during installation or transportation.
3. Check whether there is burning traces on the module back plate.
8.3
Inspection of connectors and cables
It is suggested to carry out a preventive inspection once every 6 month:
1. Check connector sealing and cable connection solidness.
2. Check whether sealant of the terminal box is cracking with gap.
Module
DualSun 300M-60-
0BBP
DualSun 305M-60-
0BBP
DualSun 310M-60-
0BBP
DualSun 315M-60-
0BBP
Open-circuit voltage [V]:
39.9
40.2
40.5
40.8
Short-circuit current [A]:
9.96
9.99
10.02
10.05
Voltage at max. power [V]:
32.3
32.7
33.1
33.5
Current at max. power [A]:
9.28
9.33
9.36
9.41
Max. power (tolerance 0,+5)
[W]:
300
305
310
315
Maximum system voltage [V]
1000
1000
1000
1000
Series Fuse Rating [A]
20
20
20
20