WFQT130005
6
V4.1B
STEP
5
Install 1/4” Plastic Tubing for Water Supply Line from
System Head Outlet to Faucet
1
Determine the length of 1/4” Plastic Tubing
L
that will be necessary to connect the System Head Outlet to the threaded Faucet
Stem. Make sure to allow enough Plastic Tubing to prevent kinking in the line.
2
Cut the 1/4” Plastic Tubing squarely on both ends with a utility knife, making sure not to crimp the Plastic Tubing during cutting.
3
Wet one end of the 1/4” Plastic Tubing with water and push it into the System Head Outlet until it stops.
4
Gently slide the plastic Compression Nut down
K
(thread side up) over the tubing. Follow with the plastic Ferrule
J
, making sure
that the Ferrule is in the proper position with the larger end on the bottom (going into the nut). Place the plastic Insert
I
into
the end of the 1/4” Plastic Tubing.
5
Firmly push the 1/4” Plastic Tubing into the end of the threaded Faucet Stem. Hand-tighten the plastic Compression Nut onto the
threads. Tighten with an adjustable wrench approximately 1/2 turn.
NOTE: Do not bend or crimp 1/4” Plastic Tubing when inserting. Do not over tighten the Compression Nut.
STEP
6
Install the QuickTwist
®
Filter
1
Hold the QuickTwist® Filter
B
with the label facing to the left slightly. The two nozzles on top of the QuickTwist® Filter should be
toward the back of the QuickTwist® Filter. If holding properly, the two extended flanges on top of the QuickTwist® Filter should be
out to each side. See Figure 6
1
at right.
2
Lift the QuickTwist® Filter straight up into the System Head
A
until the two nozzles seat into the ports and the two extended
flanges on top of the QuickTwist® Filter are fully engaged into the System Head.
3
Turn the QuickTwist® Filter left to right until it stops.
X
X
WFQT130005
6
1
2
3
A
B
X
X
WFQT130005
5
X
X
WFQT130005
4
5
K
J
I
FAUCET FOR
FILTERED WATER
3
1/4” PLASTIC TUBING
INLET
OUTLET
L
D