8 Installation 

The unit is suitable for wet locations. 

8.1 Floor 

Mounted 

Installation 

X-BRICK may be either floor or ceiling mounted. 

For floor mounted installations, X-BRICK is equipped with four rubber mounting feet on its bracket that allow 

the fixture be used as a self-standing projector. 

8.2 Ceiling 

Mounted 

Installation 

For ceiling mounted installations, DTS recommend the use of appropriate clamps to fix the unit to the mounting 

surface. 

An Omega bracket with “Fast Lock” connections, already mounted on the unit, allows to hang the X-BRICK by 

using proper truss fixing clamps. 

The supporting structure from which the unit is hung should be capable of bearing the weight of the unit, as 

should any clamps used to hang it.  

When outdoor and installing X-BRICK vertically, ensure to mount the unit with the display facing towards the 

ground. 

8.2.1 Installation With Omega Bracket 

Four ¼-turn “Fast Lock” connections placed in the base of the unit allow X-BRICK to hang by using Omega 

bracket (provided with the unit) in conjunction with an Aliscaf clamp (available on demand). 

Summary of Contents for X BRICK

Page 1: ......

Page 2: ......

Page 3: ...User Manual Ver 1 04 1 di 35 X BRICK Release 1 04 Code 0517I347 For more information Language EN All trademarks both marked and not marked are the property of their respective owners...

Page 4: ...application of the products or circuits described herein FRA Les informations contenues dans le pr sent manuel ont t r dig es et contr l es avec le plus grand soin Nous d clinons toutefois toute respo...

Page 5: ...5 7 Power Supply 9 5 8 Connections 9 5 9 Internal Protection Devices 9 5 10 Operating Temperature 9 5 11 Storage Temperature 9 5 12 Physical 9 5 13 Dimensions 10 6 Included Items 10 7 Accessories on R...

Page 6: ...1 Preparation Procedure for Cables and Connectors 21 11 2 2 Cable Folding 21 11 3 Protection 22 12 DMX Signal Connection 22 12 1 DMX terminator 23 12 2 DMX Modes 23 12 3 Setting Up the DMX Address 24...

Page 7: ...ce from any angle to avoid damage of head internal parts European Community Directive 2012 19 EU on Waste Electrical and Electronic Equipment WEEE 2 General Warning Carefully read the instruction cont...

Page 8: ...and compromising its proper operation Each fixture produces heat and must be installed in a well ventilated place Connect the projector to mains power via a thermal magnetic circuit breaker 3 2 Preven...

Page 9: ...ht of the unit Always use a safety cable to sustain the weight of the unit in case of failure of the main fixing point The external surface of the unit s body at various points may exceed 50 C Never h...

Page 10: ...ns output 15 300 lm LED lifespan 50 000 hours 70 lumen output 5 2 Optical Group 8 projection angle Range of quick mounting holographic filters included 20 40 60 x10 no mounting tools required Uniform...

Page 11: ...8 Connections X BRIK and X BRIK Wireless models only PowerCON TRUE1 In Out IP65 panel connectors w water proof caps XLR 5 pins In Out IP65 panel connectors w water proof caps X BRIK PI and X BRIK PI...

Page 12: ...10 code 0506A101 D18 Holographic filter 60 code 0506A103 D18 Holographic filter 80 code 0506A121 D18 Holographic filter 30 x60 code 0506A133 D18 Barndoor black finishing code 03 LA 237 11 Visor black...

Page 13: ...mps to fix the unit to the mounting surface An Omega bracket with Fast Lock connections already mounted on the unit allows to hang the X BRICK by using proper truss fixing clamps The supporting struct...

Page 14: ...User Manual Ver 1 04 12 di 35 X BRICK 8 2 2 Installation Without Omega Bracket...

Page 15: ...ed DTS service center A suitable safety cable code 0521A038 is available on demand You may attach the safety cable to the attachment point A located at the back of the X BRICK as shown in the picture...

Page 16: ...User Manual Ver 1 04 14 di 35 X BRICK 8 5 Movement...

Page 17: ...n the bottom side of the filter into the gap as shown in the picture below figure 1 2 Gently bend the filter 3 Position now the top side of the filter into the gap as shown in the picture below figure...

Page 18: ...he visor to the unit remove the screws as shown in the picture below marked in red and then reapply them to their former position now with the visor properly positioned in place Once installed fix the...

Page 19: ...ndoor to the unit remove the screws as shown in the picture below marked in red and then reapply them to their former position now with the barndoor properly positioned in place Once installed fix the...

Page 20: ...h pressure water jets If the product does not work the way it is meant to please contact the nearest authorized support center or refer directly to D T S Illuminazione S r l Do not try to repair the p...

Page 21: ...240Vac 50 60 Hz MAX 10A PowerCON TRUE1 female IP65 panel connector with water proof cap Max 3 X BRICK units 230Vac Max 1 X BRICK units 100Vac DMX OUT XLR 5 pole female IP65 panel connector with water...

Page 22: ...it shall be exclusively replaced by the manufacturer or his service agent or a similar qualified person in order to avoid a hazard Ergonomic double handles MAINS IN 100 240Vac 50 60 Hz Power cable 3x1...

Page 23: ...ately repaired by restoring their IP protection rating For junctions Cable Cable use permanent installation kit IP68 Power IN IP68 cable connector 2 x DMX IN OUT IP68 cable connectors code 03 LA 214 1...

Page 24: ...conductors do not touch each other Do not connect the ground cable to the XLR chassis The housing of the plug must be isolated Connect the light controller to the DMX IN panel connector of the projec...

Page 25: ...etween pin 2 and pin 3 The DMX terminator must be plugged in into the last unit s DMX OUT panel connector of the DMX line Place a 120 resistor between pin 2 and 3 of a male XRL connector Plug the resi...

Page 26: ...crolling will be quicker allowing thus for a faster selection 13 Updating the Firmware In order to update to the latest firmware release of the SYNERGY 7 PROFILE you will need DTS firmware uploader do...

Page 27: ...lay panel To return to the previous level in the menu structure without saving any changes To exit the menus ENTER To select any desired menu To confirm any selection made or save any changes UP DOWN...

Page 28: ...29 DMX channels 4 4CH GLOBAL RGBW Allows to select GLOBAL RGBW mode 4 DMX channels Single layer operation for compatibility with all BRICK models 5 6CH GLOBAL RGBW SHUT DIM Allows to select GLOBAL RGB...

Page 29: ...t 128 BLUE 0 255 Default 128 BLUE FINE 0 255 Default 128 WHITE 0 255 Default 128 WHITE FINE 0 255 Default 128 DIMMER 0 255 Default 128 DIMMER FINE 0 255 Default 128 CUSTOM2 Custom2 RGBW RGBW Fine and...

Page 30: ...menu by using an external DMX controller The unit must be set to 10 DMX channels mode Refer to REC MODE for details M001 M016 SLAVE SURE SLAVE Slave mode The unit is forced to DMX address 1 and 10 DM...

Page 31: ...istics of the tungsten halogen lamps LINEAR Allows to set linear light output SYNC 610 5000 HZ Allows to adjust the PWM frequency value Hz in order to reduce flickering in the process of your camera r...

Page 32: ...ns DEFAULT SET SURE To restore factory settings SYSTEM INFO TEMPERATURE DRV1 41 4 40 8 DRV2 40 5 41 0 LED 48 2 PSU 43 4 MICRO 1 46 6 MICRO 2 45 5 DRV 1 LED Driver Master board temperature monitoring D...

Page 33: ...optimize the wireless communication maintain TX to RX line of sight The maximum distance should not exceed 100 meters Select UNLINK menu to log off the unit from paired wireless TX device Operation a...

Page 34: ...the received input DMX values With the channel SCENES it is possible to scroll through scenes while with RECORDING it is possible to store the selected scene 235 255 The unit runs the configuration g...

Page 35: ...outputs 2 and 3 of LED Driver Master board damaged open or in short circuit Unit immediately goes in black out DRV1 NTC3 OVERTEMP Temperature detected over 100 C on outputs 2 and 3 of LED Driver Mast...

Page 36: ...RICK 17 LED Pixel Invert Function 18 Product Disposal DOCTUS are electrical devices and therefore at the end of their lifetime must be disposed according to local regulations and for no reason can the...

Page 37: ...User Manual Ver 1 04 35 di 35 X BRICK NOTES...

Page 38: ......

Page 39: ......

Reviews: