DTM System BLUE 232 Manual Download Page 3

1. Introduction

 

The BLUE 232 gate controller is used to control the drives of double-leaf gates, powered by 

alternating voltage 230V, 50Hz, with a power of max. 2 x 350W. It works with actuators equipped with limit 
switches or encoders. The driver configuration is done via the Blue Motor Control application for Android 
devices,  available  for  download  from  the  GooglePlay  store.  The  application  communicates  with  the 
controller via Bluetooth. The software has an intuitive interface, thanks to which the configuration is quick 
and efficient.
The controller has the function of slowing down the movement while stopping and regulating the power of 
the actuators. The control panel allows you to set automatic closing of the gate after a time and / or photo-
closing (activated after the photocells are violated and released again). BLUE 232 has an output for a 12 / 
24V DC gate bolt and an additional output controlled by a manual or radio button, which can work in 
bistable or monostable mode, intended for switching an external device. Radio control takes place via the 
DTM433MHz and DTM868MHz series transmitters.

2. Technical data

Basic parameters

 Power supply  

 

 

 

 

230V AC, 50 Hz

 Stanby power consumption    

 

 

5W

 Operating temperature (min./max.) 

 

 

-20°C /+55°C

 External dimensions of the casing (W x D x H) 

 

240 x 120 x 190 mm

 Mounting method   

 

 

 

surface-mounted housing

 Weight   

 

 

 

 

1,1 kg

 IP 

 

 

 

 

 

66

Outputs / inputs

 Actuator output (voltage / maximum power / 

 

   built-in capacitor / quantity)   

 

 

230VAC / 2 x 350W / none / 2  

 Signal lamp output  

 

 

 

OC max. 24VDC/6W

 Peripheral power supply output (photocells, lock, etc.) 

24V DC, 0,5A

 Power output for photocell transmitters   

 

OC type (see PHOTO-TEST function)

 Gate bolt output 

 

 

 

 

12 / 24V DC, switched for 5 sec. when opening begins

 Additional output in bistable / monostable mode 

 

relay (potential-free), max. 1A / 30V AC / DC

 Photocell inputs / quantity 

 

 

 

programmable, NC type / 3

 Manual control input A, B, C   

 

 

programmable, NO type

 Manual control STOP input   

 

 

NC type

 Limit switches input 

 

 

 

on opening and closing / NC type / 4

 Motor encoder input 

 

 

 

digital / 2

Control part

 Adjustable opening and closing time / soft stop phases 

1 - 120s / 0 - 15s with an accuracy of 1s

 Adjusting the power of the actuators 

 

 

10-100 separately for the 1st and 2nd actuators, via the app

 Increasing the programmed power of actuators 

 

yes, separately for each actuator 0-50%

 Second leaf delay adjustment  

 

 

yes, time adjustable separately for opening and closing 0-60s

 Programming the controller operation 

 

 

using Bluetooth application

 Gate auto-closing function 

 

 

 

yes, time adjustable from 1 to 120s

 Photo-closing function 

 

 

 

yes, time separately adjustable 0-120s

 Pushing with increased force after closing, 
 start with increased force 

 

 

 

programmable

 Preliminary operation of the signal lamp  

 

programmable, 5s 

 Photocell test (testing of photocells before door movement)  programmed separately for each photocell input

 User Interface 

 

 

 

 

SW button, LED indicators, application for configuring the controller 

 

 

 

 

 

 

operating parameters via Bluetooth

 Device configuration memory   

 

 

non-volatile

Radio part

 Frequency 

 

 

 

 

433MHz and 868MHz

 Antenna input impedance 

 

 

 

50 

W

 

Antennas 

 

 

 

 

wire, terminals for connecting external antennas

 

Memory capacity   

 

 

 

200 remotes, each with an individual number in memory

 Remote configuration 

 

 

 

assigning the controller function to any remote control button

 Possibility to erase all memory 

 

 

yes

 Possibility to delete a single remote control 

 

yes

 Possibility to add a remote control without interfering 
 with the controller   

 

 

 

yes, the function of remote assigning the remote control

 

 

 

 

 

 

/ via Bluetooth ™Bluetooth

 Blocking the remote assigning function 

 

 

yes

T

echnical data / Introduction

3

Summary of Contents for BLUE 232

Page 1: ...AUTOMATION SYSTEMS DOUBLE LEAF GATE CONTROLLER manual version 1 6 BLUE 232 DTM System ul Brzeska 7 85 145 Bydgoszcz tel fax 52 340 15 83 340 15 84 www dtm pl dtm dtm pl ...

Page 2: ......

Page 3: ...opening begins Additional output in bistable monostable mode relay potential free max 1A 30V AC DC Photocell inputs quantity programmable NC type 3 Manual control input A B C programmable NO type Manual control STOP input NC type Limit switches input on opening and closing NC type 4 Motor encoder input digital 2 Control part Adjustable opening and closing time soft stop phases 1 120s 0 15s with an...

Page 4: ...4 ...

Page 5: ...tions is responsible for any damage that the device may cause 3 2 Description of the device and installation method The BLUE 232 controller includes a motherboard and a housing The housing has four points for mounting it on a vertical surface 1 and cable glands on each side The main board fig 2 should be screwed to points 2 in fig 1 The controller is equipped with a Bluetooth communication system ...

Page 6: ...on 11 aditional relay output NO 12 LED lamp connector ground potential max 6W gate lock output 12 24V DC power supply 24V 13 connection for connecting the limit switches of the actuator 1 14 connector for connecting the limit switches of the actuator 2 15 connector for connecting the encoder of the actuator 1 16 connector for connecting the encoder of the actuator 2 17 connector for connecting the...

Page 7: ... should be connected to CAP1 and CAP2 connectors 3 3 4 Terminals for connecting a 24V 6W signal lamp Clamps are used to connect a 24V LED lamp with a maximum power of 6W Connect it to the LAMP and 24V terminals fig 2 In the case of a lamp with a built in interrupter turn off the interrupter function in the controller 3 3 5 Clamps for connecting the gate bolt The controller is equipped with an outp...

Page 8: ...allel to the entrance edge 3 3 9 Manual control terminals INPUT STOP and A B C The NC type safety button must be connected to the INPUT STOP terminals If the button is not used short circuit the terminals with a wire Momentary NO type buttons can be connected to A B C terminals which will control the drive operation in accordance with the program settings Make the settings from the level of the Bl...

Page 9: ...cation CAUTION The control panel settings that are not adjusted to the installation conditions may soon lead to its destruction and loss of warranty After completing the stage of creating the installation and connecting devices it is necessary to program the control panel in order to adjust its operating parameters to the current installation in particular always adjust the power of the actuators ...

Page 10: ...ary to re synchronize the gate leaves which should be done as follows trigger the OPEN movement wait until both leaves are fully opened it may be necessary to first call the CLOSE direction and then OPEN direction 5 Programming the BLUE 232 controller The BLUE 232 controller is programmed to the needs of a given installation using a dedicated Blue Motor Control application forAndroid devices commu...

Page 11: ... In order to use the application to configure the device it is necessary to pair the controller Bluetooth interface with the device from which the configuration will be carried out eg a telephone 5 2 1 Launching theApplication and Bluetooth communication Run the Blue Motor Control application and if Bluetooth was not previously turned on in the phone let the application turn it on Programming Figu...

Page 12: ...l panels are to be operated nearby select the one you want to configure from the list 5 2 3 PIN code for the controller If the application connects to the controller for the first time it will ask for a pin code 0000 by default Figure 7 Search and select a controller fron the list Figure 8 PIN code request on first startup ...

Page 13: ...ttings Restoring the factory settings does not remove the remotes from the controller memory CAUTION Lowering the operating power of the actuators has a positive effect on safety conditions as well as on the service life of the mechanical elements of the installation CAUTION Violation of the photocells and blocking the gate during the learning process will not stop the actuator If necessary the ga...

Page 14: ... installed the OP photocells must be manually violated the OP LED should go out on the control board Do the same for the CL photocell and OP CL if fitted In the rest state when the optical barriers are not violated the OP CL OP CL diodes should be on If it is not it means an error in the operation of the photocells incorrect connection not synchronizing the transmitter with the receiver or photoce...

Page 15: ... System provides the devices that are operational and ready for use The warranty is granted for a period of 30 months from the date of sale by the manufacturer The warranty period is determined based on the manufacturer s warranty seals identifying the production batch placed on each product To recognize the warranty it is necessary to present a sales document The manufacturer undertakes to repair...

Page 16: ...DTM System ul Brzeska 7 85 145 Bydgoszcz Polska http www dtm pl e mail dtm dtm pl D E S I G N A N D P R O D U C T I O N O F E L E C T R O N I C D E V I C E S ...

Reviews: