44 Appendix C: Quick Reference
Appendix C: Quick Reference
In the section below, you will have a full view of configuration items. You may use this guide to quickly set up
your IP1200C. If you reset IP1200C, only IP Address, Gateway IP, Subnet Mask, DNS and Telnet Password items
will be retrieved to the factory default.
Configuration Items
After you enter Telnet program, you will find the configuration items as below.
Items Functions
Format
Default
settings
(0) Device ID
The ID Number of your
IP1200C. It is also the prefix of
per port’s ID which is Device ID
plus port number. Non-editable.
Device ID: 5-digit
Port ID: 6-digit
(Device ID + Port
Number)
xxxxx
Port 1: xxxxx1
Port 2: xxxxx2
etc.
(1) IP Address
A static IP address assigned to
IP1200C
xxx.xxx.xxx.xxx 192.168.1.200
(2) Gateway IP
The IP address of the gateway
on your LAN
xxx.xxx.xxx.xxx 192.168.1.254
(3) Subnet Mask
The subnet of your IP1200C
xxx.xxx.xxx.xxx 255.255.255.0
(4) DNS
Your Domain Name Service xxx.xxx.xxx.xxx 168.95.1.1
(5) DHCP
Used when your network is in
DHCP environment.
0: Off 1:On
Off
(6) Play Volume
Adjust the playing volume level 1 to 9
5
(7) Record Volume
Adjust he recording volume
level
1 to 9
5
(8) Echo Cancellation
Adjust the echo cancellation
level. If it is set as 0, this
function is disabled.
0 to 2
2
(9) Long Distance Code
Your long distance code
-
(10) International Code
Your international access code
-
(11) Country Code
Your country code
-
(12) Password for FXO
Password for accessing FXO
ports. If empty, no password is
required.
Maximum 10 digits -
(13) Password for FXS
Password for accessing FXS
ports. If empty, no password is
required.
Maximum 10 digits -
(14) Telnet Password
Password of accessing IP1200C
via Telnet. To disable the Telnet
function, press the SECURITY
button.
Maximum 10
characters and/or
digits
0000 (four zero,
shown as ****)
(15) Port Configurations
To enable or disable ports. Used
when specific ports are broken
down.
Port Status
1:Enable 0:Disable
All enable
(16) Busy Tone Setup
1. Busy tone cycles
hangup
2. Minimum busy tone
length
3. Maximum busy tone
length
4. Busy tone length
tolerance
1. After detecting set busy tone
cycles, connection will be
released.
2. Set the minimum length of a
busy tone.
3. Set the maximum length of a
busy tone.
Using the above 2 and 3 to set
the valid range of a busy tone.
4. The tolerance between two
valid busy tones.
2 to 9
100 to 1200 ms
100 to 1200 ms
20 to 400 ms
4 cycles
200 ms
600 ms
80 ms
(17)Advanced Options
1. Max. One-Way silence
1. When the silence of any side
exceeds this duration, calls will
be terminated.
10 to 720 min
30 min