These three parameters: Protocol, Baud rate and address is set using DIP switches within
the camera.
Set Protocol
The cameras support the standard control protocols Pelco P and Pelco D, supported by the
majority of the consoles and DVRs. The recognition of the protocol is automatic and requires
no settings on the camera.
Set Baud rate and address
The speed communications parameters (baud rate) and the camera address is
set through
microswitches present on board room.
The proper setting of the microswitches is the first operation to be still perform before
proceeding to the assembly. The factory setting is:
BAUD RATE 2400 BPS ADDRESS: 1
On the camera motherboard there are 2 blocks of microswitches: one from 4:01 to 8 switches.
The microswitch 4 block is used to set the baud rate.
Group 4 switches
Switch No.
1
2
3
4
Baud rate
( BPS )
( BPS )
( BPS )
ON OFF OFF OFF
2400
OFF ON OFF OFF
4800
ON ON OFF ON
9600
The second block of 8 microswitches allows to set the camera address according to the
following table. This
type of
assignment is
defines
HARDWARE ADDRESS.
It 'also possible, as we will see a software assignment via the OSD menu of the camera, but
it is good to reserve a qualified expert when you need to operate a lot of speed dome
cameras in the same installation.
The camera is set
with address 1 Factory.
E 'can set any address between 1 and 255 as
The camera is set
with address 1 Factory.
E 'can set any address between 1 and 255 as
The camera is set
with address 1 Factory.
E 'can set any address between 1 and 255 as
long as different for each camera.