Appendix C: Regulatory Approvals Information
SIA False Alarm Reduction Installations
&DXWLRQ
Call Waiting Cancel (Section [382], Option 4) feature on a non-Call Waiting line will prevent successful communication to the supervising station.
1RWHV
Programming at installation may be subordinate to other UL requirements for the intended application.
Cross zones have the ability to individually protect the intended area (e.g. motion detectors which overlap).
Cross zoning is not recommended for line security Installations nor is to be implemented on exit/entry zones.
There is a communication delay of 30 seconds in this control panel. It can be removed, or it can be increased up to 45 seconds at the option of the end user by consulting with
the installer.
Do not duplicate any reporting codes. This applies for all communication formats other than SIA or CID sending automatic programmed reporting codes.
The security system shall be installed with the sounding device activated and the communicator enabled for transmission using SIA or CID format.
6,$)HDWXUH
3URJUDPPLQJ6HFWLRQ
&RPPHQWV
5DQJH'HIDXOW
5HTXLUHPHQW
Exit Time
[005], 3rd entry
Access to Entry and Exit delays and Bell Time Out for the system
Range
:
45- 255 seconds
Default:
60 sec.
Required
(programmable)
Exit Time Restart
[018], Option 7 ON
Enables the exit delay restart feature
Default:
Enabled
Required
Auto Stay Arm on
Un-vacated Premises
[001] Zone type 05, 06, 32
Function Key: Stay Arming. All Stay/Away type zones (05, 06, 32) will be auto-
matically bypassed
If no exit after full arm
Default:
Enabled
Required
Entry delay(s)
[005], 1st and 2nd entry
Access to Entry and Exit delays and Bell Time Out for the system
Note:
Combined Entry delay and Communications Delay (Abort Window) shall
not exceed 60s
Range:
30 sec. to 4 min.
Default:
30 sees
Required
(programmable)
Abort Window
for Non-Fire zones
[101]-[108] bit 7 ON
Access to zone attributes, i.e, swinger shutdown, transmission delay and cross
zone. Individual zones attribute bit 7 (Transmission delay) is by default ON
May be disabled
by zone or zone type
Default:
Enabled
Required
Abort Window Time - for
Non-Fire zones
[377], 4th entry
Access to the programmable delay before communicating alarms
Note:
Combined Entry delay and Communications Delay (Abort Window) shall
not exceed 60s
Range:
20 - 45 sec.
Default:
30 sees
Required
(programmable)
Abort Annunciation
[382], Option 3 ON
Enables the “Communication Cancelled” message display on keypad
Annunciate that no
alarm was transmitted
Default:
Enabled
Required
Cancel Annunciation
[328], 8th entry
Access to the reporting code for Alarm Cancelled
Annunciate that a
Cancel was transmitted
Default:
Enabled
Required
Cancel Window
[377], 10th entry
When an access code is entered during the cancel window, a Communications
Cancelled reporting code is sent.
Range:
005-255 min.
Default:
000
Required
Duress Feature
[*][5] Master Code
Option 2 ON
Do not derive code from an existing Master/User code (e.g., Master code is 1234,
the duress code should not be 1233 or 1235)
No 1+/- derivative of another
user code. No duplicates with
other user codes
Default:
disabled
Allowed
Cross Zoning
[018] Option 6
[101]-[108] bit 8 OFF
This option enables Cross Zoning for entire system. Individual zones can be
enabled for Cross zoning via Zone attribute bit 8 in sections [101]-[108].
Programming required
Default:
Disabled
Required
Cross Zone Timer
[176]
Access to the programmable Cross Zone timer
May program
Range: 001-255 sec./min.
Default:
60 seconds
Allowed
Swinger Shutdown for Alarms
[377] 1st entry
Access to the swinger shutdown limit for zone alarms.
For all non-fire zones
shut down at 1 to 6 trips
Default:
2 trips
Required
(programmable)
Swinger Shutdown Enable
[101] - [108] bit 6 ON
Access to zone attributes, i.e., swinger shutdown, transmission delay and cross
zone. Individual zones attribute bit 6 (Swinger shutdown enabled) is by default ON
For non-police
response zones
Default:
Enabled
Allowed
24-Hr. Auto-verified Fire
[001] Zone type 29
Access to 24-Hr. Auto-verified Fire
Activates if a restore is not
received within the specified
time
Default:
Disabled
Required
Call Waiting Cancel Dial
String
[304], [382], Option 4 OFF
Access to the dialing sequence used to disable call waiting
Dependant on user phone line
Default:
disabled
Required
System Test:
[*][6] Master Code, Option 4
The system activates all keypad sounders, bells or sirens for 2 seconds and all keypad lights turn on.
Refer to the
User Manual (part no. 29008014).
Alarm Communications
During Walk Test
[382] Option 2
Enables communication of zone alarms while Walk Test is active.
Walk Test End and Begin
Reporting Codes
[348], 1
st
and 2
nd
Entries
Access to the reporting codes for Walk Test Begin and Walk Test End.