5 Programming Worksheets
31
Zone Follower PGM requires 2 programming sections for attributes: the normal PGM attribute Sections [501-514] and Sections [551-
564] for zone assignment.
[551]-[564] PGM Zone Assignment
21
Command Output #3 [*][7][3]
22
Command Output #4 [*][7][4]
23
For Future Use
24
For Future Use
25
Delayed Burglary and Fire Bell
Output
26
Battery Test Output
27
Police Code
28
For Future Use
29
Zone Follower
30
Status Alarm Memory
Notes:
A change of default setting will NOT affect the output.
A change of default setting will affect the output.
Attribute:
1
2
3
4
5
6
7
8
ON
OFF
Service Req.
Event
AC Fail
TLM Fault FTC Enabled Device Fault Device
Tamper
Device Low
Battery
Loss of
Clock
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
09 System Trouble
Attribute:
1
2
3
4
5
6
7
8
ON
OFF
Burglary
Event
Fire
Event
Panic Event
Medical
Event
Supervisory
Event
Priority
Event
Duress Event
Output
Follows
Timer
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
10 System Event
Note:
If a System Event PGM is programmed to follow the Command Output Timer, attribute 8 must be enabled.
Location
PGM 29 Zone Follower
Option On
Option Off
Option 1
For Future Use
Option 2
For Future Use
Option 3
True Output
Inverted
Option 4
For Future Use
Option 5
For Future Use
Option 6
For Future Use
Option 7
For Future Use
Option 8
AND Logic
Or Logic
Section Number
Output Number
Zone Follower Zone
Main Board
1
2
3
4
5
6
7
8
[551]
PGM 1
[552]
PGM 2
PC5208
[553]
PGM 3
[554]
PGM 4
[555]
PGM 5
[556]
PGM 6
1
2
3
4
5
6
7
8
PGM
Option
=ON
OFF
Not Used
–
Not Used
–
True Output
Inverted
Follows Timer
ON/OFF
Code Req.
No Code
Not Used
No
Not Used
No
Not Used
No