Trouble
indication
Trouble
Indicator Digit
Possible
Causes
Trouble Possible Solution
Yellow LED
– 8 Flashes
08
Receiver
Supervision
Trouble
l
This trouble is indicated when supervision is enabled and the unit
is not able to successfully communicate with the receiver.
l
If this trouble persists, contact the central station.
Yellow LED -
9 Flashes
09
FTC Trouble
l
The unit has exhausted all communications attempts to all
programmed receivers for events generated by the communicator.
l
Restart the system, if trouble persists, contact the dealer.
Yellow LED
– 12 Flashes
0C
Module
Configuration
Trouble
l
This indication appears when section [021] system account code
or sections [101], [111], [201], and [211] receiver account code
have not been programmed. Ensure that a valid account code has
been entered in these sections.
All LEDs
flashing
together
N/A
Boot Loader
Failed
l
Disconnect power, then reconnect power to the communicator
module.
Red and
Yellow LEDs
flashing
together
N/A
Initialization
Sequence
l
The unit is still initializing, please wait while the unit gets its
programming and establishes a connection to all programmed
receivers.
NOTE:
This process may take several minutes to complete.
Only Green
LEDs
flashing
N/A
Hardware Default
Jumper
l
The hardware default jumper is installed and must be removed.
See Figure 3.
Green LEDs
alternating
N/A
Radio Reset or
Radio
Initialization
l
If this status persists and the yellow LED shows 5 flashes, confirm
that the SIM card is active.