Event [Section] Label
Default Label
Event [Section] Label
Default Label
[869] Keypad Message
(Keypad Message)
[870] Function Successful (Successful)
[871] Function Failure
(Unsuccessful)
[872] Invalid Command
(Invalid Command)
[873] System Stay Armed (Stay Armed)
[874] System Away Armed (Away Armed)
[875] System Night
Armed
(Night Armed)
[876] System Disarmed
Ready
(Disarmed Ready)
[877] System Disarmed,
Not Ready
(Disarmed Not Ready)
[878] System In Alarm
(is in Alarm)
[879] Trouble Label
(Service is Required)
[880] No Alarms in
Memory
(No Alarms in Memory)
[881] Pay As You Go
Balance
(Pay as you go balance:)
[882] Pay As You Go
Message
(*123#)
[883] Response Code
(Response Code)
Receiver Diagnostic Testing
[901] Diagnostic Test Transmission
[1] Ethernet 1
Default (OFF).
[2] Ethernet 2
Default (OFF).
[3] Cellular 1
Default (OFF).
[4] Cellular 2
Default (OFF).
[5],[6],[7],[8] Reserved
(OFF).
This section may be used by the installer to force the communicator to send an immediate test trans-
mission to specific receivers, to verify that the communications paths are available. Diagnostic test trans-
mission failure will indicate as FTC trouble (yellow LED = 9 flashes). If an FTC error occurs when testing
all receivers, select only one receiver and repeat test to isolate the receiver that is not communicating.
NOTE:
Sending a test transmission to a receiver that is not programmed generates an FTC trouble.
[961] Cellular Inactivity Timeout
Default (41) Valid entries are 00 - FF.
[962] CREG Max Registration
Default (C8) Valid entries are 00 - FF.
[963] Retransmission Delay
Default (2D) Valid entries are 00 - FF.
[964] Voice Volume
Default (04) Valid entries are 00 - FF.
[965] Microphone Gain
Default (01) Valid entries are 00 - FF.
[966] SMS Recovery Hour
Default (0018) Valid entries are 0000 - FFFF.
[967] SMS Threshold 1
Default (0032) Valid entries are 0000 - FFFF.
[968] SMS Threshold 2
Default (0064) Valid entries are 0000 - FFFF.
[969] Debug Mask Timeout
Default (2760) Valid entries are 0000 - FFFF.
[970] Monitoring Heartbeat
Default (0060) Valid entries are 0000 - FFFF.
System Information (Read Only)
NOTE:
Sections [971] - [998] are provided for information (read-only). Values in these sections cannot
be modified by the installer.
38