28
S E C T I O N 1 0
System Programming
[001] VPM5580TC Service Code
Default
5580
l_____l_____l_____l_____l
Enter 4 decimal digits
[002] First System Options
Default
Option ON
Option Off
ON
l________l
Option 01
Partition 1 Access Enabled
Partition 1 Access Disabled
OFF
l________l
Option 02
Partition 2 Access Enabled
Partition 2 Access Disabled
OFF
l________l
Option 03
Home Automation Enabled
Home Automation Disabled
OFF
l________l
Option 04
Automation requires
No access code req’d
access code
for Automation
OFF
l________l
Option 05
AC = 50Hz
AC = 60 Hz
OFF
l________l
Options 06-08 For Future Use
[003] Status Prompt Mask
Default
Option ON
Option Off
ON
l________l
Option 01
Warning, Bypass On
Warning, Bypass On
Warning, Bypass On
Warning, Bypass On
Warning, Bypass On
Prompt enabled
Prompt disabled
ON
l________l
Option 02
System Trouble ....
System Trouble ....
System Trouble ....
System Trouble ....
System Trouble ....
Prompt enabled
Prompt disabled
ON
l________l
Option 03
System Open, Zone ....
System Open, Zone ....
System Open, Zone ....
System Open, Zone ....
System Open, Zone ....
Prompt enabled
Prompt disabled
ON
l________l
Option 04
Alarms in Memory
Alarms in Memory
Alarms in Memory
Alarms in Memory
Alarms in Memory
Prompt enabled
Prompt disabled
ON
l________l
Option 05
Service Required
Service Required
Service Required
Service Required
Service Required
Prompt enabled
Prompt disabled
ON
l________l
Option 06
AC Power Trouble
AC Power Trouble
AC Power Trouble
AC Power Trouble
AC Power Trouble
Prompt enabled
Prompt disabled
ON
l________l
Option 07
Telephone Line Trouble
Telephone Line Trouble
Telephone Line Trouble
Telephone Line Trouble
Telephone Line Trouble
Prompt enabled
Prompt disabled
ON
l________l
Option 08
Communication Trouble
Communication Trouble
Communication Trouble
Communication Trouble
Communication Trouble
Prompt enabled Prompt disabled
ON
l________l
Option 09
Zone Fault
Zone Fault
Zone Fault
Zone Fault
Zone Fault
Prompt enabled
Prompt disabled
ON
l________l
Option 10
Zone Tamper
Zone Tamper
Zone Tamper
Zone Tamper
Zone Tamper
Prompt enabled
Prompt disabled
ON
l________l
Option 11
Zone Low Battery
Zone Low Battery
Zone Low Battery
Zone Low Battery
Zone Low Battery
Prompt enabled
Prompt disabled
ON
l________l
Option 12
Time and Date Incorrect
Time and Date Incorrect
Time and Date Incorrect
Time and Date Incorrect
Time and Date Incorrect
Prompt enabled Prompt disabled
Programming Worksheets
29
[004] Star Function Prompt Mask
Default
Option ON
Option Off
ON
l________l
Option 01
For Zone Bypassing
For Zone Bypassing
For Zone Bypassing
For Zone Bypassing
For Zone Bypassing
Prompt enabled
Prompt disabled
ON
l________l
Option 02
For System Troubles
For System Troubles
For System Troubles
For System Troubles
For System Troubles
Prompt enabled
Prompt disabled
ON
l________l
Option 03
For Alarm Memory
For Alarm Memory
For Alarm Memory
For Alarm Memory
For Alarm Memory
Prompt enabled
Prompt disabled
ON
l________l
Option 04
For Door Chime Control
For Door Chime Control
For Door Chime Control
For Door Chime Control
For Door Chime Control
Prompt enabled
Prompt disabled
ON
l________l
Option 05
For Automation Control
For Automation Control
For Automation Control
For Automation Control
For Automation Control
Prompt enabled
Prompt disabled
ON
l________l
Option 06
For Special Functions
For Special Functions
For Special Functions
For Special Functions
For Special Functions
Prompt enabled
Prompt disabled
ON
l________l
Option 07
For “Output Control”
For “Output Control”
For “Output Control”
For “Output Control”
For “Output Control”
Prompt enabled
Prompt disabled
ON
l________l
Option 08
For Arming Without Entry
For Arming Without Entry
For Arming Without Entry
For Arming Without Entry
For Arming Without Entry
Prompt enabled Prompt disabled
ON
l________l
Option 09
For Quick Arming
For Quick Arming
For Quick Arming
For Quick Arming
For Quick Arming
Prompt enabled
Prompt disabled
OFF
l________l
Option 10
For Quick Exit
For Quick Exit
For Quick Exit
For Quick Exit
For Quick Exit
Prompt enabled
Prompt disabled
ON
l________l
Option 11
To Arm Interior Zones
To Arm Interior Zones
To Arm Interior Zones
To Arm Interior Zones
To Arm Interior Zones
Prompt enabled
Prompt disabled
ON
l________l
Option 12
For Volume Control
For Volume Control
For Volume Control
For Volume Control
For Volume Control
Prompt enabled
Prompt disabled
ON
l________l
Option 13
For Speech Rate Control
For Speech Rate Control
For Speech Rate Control
For Speech Rate Control
For Speech Rate Control
Prompt enabled
Prompt disabled
OFF
l________l
Options 14-15 For Future Use
ON
l________l
Option 16
For User Programming
For User Programming
For User Programming
For User Programming
For User Programming
Prompt enabled
Prompt disabled
[005] Local Programming Lockout Counter
Default: 000
l_____l_____l_____l
(Valid entries are 000-255 attempts)
[006] Local Programming Lockout Duration
Default: 000
l_____l_____l_____l
(Valid entries are 000-255 minutes)
[007] Number of Home Automation Transmissions
Default: 001
l_____l_____l_____l
(Valid entries are 000-255 powerline transmissions)
[008] Thermostat Prompt Mask
Default
Option ON
Option Off
ON
l________l
Option 01
To Set Temperature
To Set Temperature
To Set Temperature
To Set Temperature
To Set Temperature
Prompt enabled
Prompt disabled
ON
l________l
Option 02
For Occupancy Mode
For Occupancy Mode
For Occupancy Mode
For Occupancy Mode
For Occupancy Mode
Prompt enabled
Prompt disabled
ON
l________l
Option 03
For Thermostat Mode
For Thermostat Mode
For Thermostat Mode
For Thermostat Mode
For Thermostat Mode
Prompt enabled
Prompt disabled
ON
l________l
Option 04
For Fan Control
For Fan Control
For Fan Control
For Fan Control
For Fan Control
Prompt enabled
Prompt disabled
ON
l________l
Option 05
Occupancy Mode Is Aux.
Occupancy Mode Is Aux.
Occupancy Mode Is Aux.
Occupancy Mode Is Aux.
Occupancy Mode Is Aux.
Prompt enabled Prompt disabled
ON
l________l
Option 06
Occupancy Mode Is Day
Occupancy Mode Is Day
Occupancy Mode Is Day
Occupancy Mode Is Day
Occupancy Mode Is Day
Prompt enabled
Prompt disabled
ON
l________l
Option 07
Occupancy Mode Is Away
Occupancy Mode Is Away
Occupancy Mode Is Away
Occupancy Mode Is Away
Occupancy Mode Is Away
Prompt enabled Prompt disabled
ON
l________l
Option 08
Occupancy Mode Is Night
Occupancy Mode Is Night
Occupancy Mode Is Night
Occupancy Mode Is Night
Occupancy Mode Is Night
Prompt enabled Prompt disabled
OFF
l________l
Option 9-16
For Future Use
For Future Use
For Future Use
For Future Use
For Future Use
[021] Telephone Access Options
Default
Option ON
Option Off
OFF
l________l
Option 01 Local Access Only
Remote and Local Access enabled
OFF
l________l
Option 02 Access code always req’d
No code req’d for security system
for security system access
access
Local Access Only must be ON for UL Listed installations.