English
I NS TAL L ATI O N MA N U A L
8. Maintenance
The appliance must be inspected once per year by a skilled installer in the field of gas-fired heating, and repaired
if necessary.
Check at least whether the appliance is working properly and safely.
!Caution
-
Always close the gas tap during maintenance work;
-
Check the gastightness after repair;
-
After replacing thermocouple 1 you should first tighten the gland nut by hand and then give it another
quarter turn with a suitable spanner;
-
You are not allowed to turn the pilot flame lower by using the settings on the gas control.
Ø
If required, clean the following components:
-
the pilot burner (malfunction search diagram, Appendix 1);
-
the space surrounding the pilot burner;
-
the glass pane(s).
!Caution
-
Remove/place the glass pane(s) as described in section 5.9;
-
Remove the deposit on the inside of the glass pane(s) with a damp cloth or a non-abrasive detergent such
as copper polish or a ceramic hot plate cleaner;
-
Avoid/remove fingerprints on the glass pane(s), since otherwise they will burn into the surface;
-
Replace a broken and/or cracked glass pane(s) as described in section 5.9.
!Caution
If necessary, replace the wood or pebble set correctly; for this, see section 5.8.
Ø
Inspect the flue gas discharge system.
!Caution
You must always perform a final inspection.
Ø
Perform the inspection as described in chapter 7.
8.1 Parts
Parts requiring replacement can be obtained from your supplier.
UK
Summary of Contents for G20
Page 28: ...E n g l i s h INSTALLATION MANUAL UK A C B C 38c 1461 A B 38c 1 462 3a 2 3b 3c ...
Page 32: ...E n g l i s h INSTALLATION MANUAL UK E 38p 0029 A B C D A 38p 0030 B 38p 0031 10a 10b 10c ...
Page 33: ...E n g l i s h INSTALLATION MANUAL UK C 38p 0032 D 38p 0033 E 38p 0034 10d 10e 10f ...
Page 34: ...E n g l i s h INSTALLATION MANUAL UK 38p 0035 38p 0062 10g 10h ...
Page 37: ...E n g l i s h INSTALLATION MANUAL UK 38p 0181 5mV 38p 0182 20mm 25mm 38c 1471 1 16 17 18 ...
Page 38: ...E n g l i s h INSTALLATION MANUAL UK ...