Report No. F09-130

INSTALLER: Leave this manual with the appliance.

CONSUMER: Retain this manual for future reference.

 WARNING: Carefully review the instructions supplied with the decorative type unvented room heater for 

the minimum fi replace size requirement.

DO NOT INSTALL THE APPLIANCE IN THIS FIREBOX, UNLESS THIS FIREBOX MEETS THE MINIMUM 
DIMENSIONS REQUIRED FOR THE INSTALLATION.

       

WARNING:

FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious injury, death, or property damage.

-   Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other 

appliance.

 -  WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance. 
•  Do not touch any electrical switch; do not use any phone in your building. 
•  Leave the building immediately.
• Immediately call your gas supplier from a neighbor’s phone.  Follow the gas supplier’s instructions. 
•  If you cannot reach your gas supplier, call the fi re department.

 -  Installation and service must be performed by a qualifi ed installer, service agency or the gas supplier.

      WARNING: FOR USE ONLY WITH A LISTED, GAS-FIRED UNVENTED DECORATIVE ROOM HEATER NOT TO 
EXCEED 40,000 BTU/H.

 
DO NOT BUILD A WOOD FIRE.

Summary of Contents for Valiant32ZP2

Page 1: ...G FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury death or property damage Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave the building immedia...

Page 2: ...s WARNING Do not use a blower insert heat exchanger insertorotheraccessorynotap proved for use with this firebox IMPORTANT Read this owner s manualcarefullyandcompletely before trying to assemble op erate or service this fireplace Improper use of this fireplace can cause serious injury or death from burns fire explo sion electricalshockandcarbon monoxide poisoning DANGER Carbonmonoxide poisoning m...

Page 3: ...hen they are in the same room with the ap pliance 1 Do not use this firebox as a wood burning fireplace Use only decorative unvented room heaters log sets 2 Do not add extra logs or ornaments such as pine cones vermiculite or rock wool Using these added items can cause sooting 3 Use only the provided hood See Parts pages 18 and 19 The firebox canopy hood must not be modified or replaced with a can...

Page 4: ...e models CANNOT be installed in a bedroom unless maximum Btu rating of installed vent free log set is less than 10 000 Btu hr 4 Proper air for combustion and ventilation page 7 COMMONWEALTH OF MASSACHU SETTS REQUIREMENTS These appliances are approved for installa tion in the US state of Massachusetts if the following additional requirements are met Un vented Room Heaters shall be in stalled in acc...

Page 5: ...6 3 8 Standoffs 221 2 321 4 361 2 41 4 n g es 5 8 Figure 1 Firebox Dimensions 32 Models Right Side View Front View 32 MODELS Outside Air Kit Location Optional Left Side View with Air Kit Back View Top View Firebox Top View 9 93 4 19 3 8 16 5 8 15 8 35 8 81 8 2 7 8 85 8 Built Side Nailin Flang Square Gas Line Access Holes ...

Page 6: ...RODUCT SPECIFICATIONS Continued Figure 2 Firebox Dimensions 36 and 42 Models 36 AND 42 MODELS Note If only one dimension is shown dimension is the same for both 36 and 42 models Firebox Top View 13 11 16 36 Models 12 3 8 42 Models 7 1 4 36 Models 9 42 Models 2 9 16 101 2 36 Models 121 2 42 Models Outside Air Kit Location Optional Left Side View with Air Kit 13 3 4 36 Models 15 5 8 42 Models 2 5 8 ...

Page 7: ...ion you must provide additional fresh air Unusually tight construction is defined as construction where a walls and ceilings exposed to outside atmosphere have a continuous water vapor retarder with a rating of one perm 6 x 10 11 kg per pa sec m2 or less with openings gasketed or sealed and b weather stripping has been added on openable windows and doors and c caulking or sealants are applied to a...

Page 8: ...he outdoors and vents to the outdoors Example Gas water heater _________ Btu Hr Vent free heater ________ Btu Hr Total ________ Btu Hr AIR FOR COMBUSTION AND VENTILATION Continued 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used _________ Btu Hr maximum the space can support _________ Btu Hr actual amount of Btu Hr used Example 63 360 Btu Hr maximum the spac...

Page 9: ...ation for required size of ventilation grills or ducts IMPORTANT Do not provide openings for inlet or outlet air into attic if attic has a thermostat controlled power vent Heated air entering the attic will activate the power vent INSTALLATION Or Remove Door into Adjoining Room Option 3 Ventilation Grills Into Adjoining Room Option 2 Ventilation Grills Into Adjoining Room Option 1 12 12 Outlet Air...

Page 10: ...ombus tible material must be 4 from side of fireplace cabinet see Figure 5 B Clearances from top of firebox opening to ceiling should not be less than 42 C When firebox is installed on carpeting or other combustible material other than wood flooring firebox should be installed on a metal or wood panel extending full width and depth of enclosure D Clearances from bottom of firebox to floor is 0 INS...

Page 11: ...ox in front of rough open ing with back of firebox inside wall open ing IMPORTANT If installing a perimeter trim kit see instructions included with trim accessory You must install shoulder screws from trim kit now Figure 6 Minimum Mantel Clearances for Built In Installation Supplied Firebox Hood Must Be Used at All Times Wire mesh Screen Firebox Noncombustible Material May Project Off this Surface...

Page 12: ...LATION Continued Figure 8 Attaching Firebox to Wall Studs Nailing Flanges Nails or Wood Screws WARNING Do not allow any combustiblematerialstooverlap firebox front facing IMPORTANT Noncombustible materials such as brick tile etc may overlap front facing but should never cover any necessary openings like louvered slots WARNING Do not allow noncombustible materials to cover any necessary openings li...

Page 13: ... modify fireplace spacers INSTALLING GAS LINE NOTICE Aqualifiedserviceper son must connect heater to gas supply Follow all local codes IMPORTANT See Connecting to Gas Supply in your log set owner s manual for details on gas hookup You may run gas line from either side or back of firebox see Figure 9 Decide which side you want to run gas line from Note This is one option for installing shutoff valv...

Page 14: ...to front hole on right side of firebox and fasten using remaining Phillips screw Hood Remove Replace Side Screws Loosen Top Screws Figure 12 Hood Placement Model May Vary From Illustration Hood INSTALLING FIREPLACE HOOD AND SCREEN 1 For Indoor models attach hood and front panel assembly by snapping panel assem bly into fireplace opening see Figure 12 OPTIONAL OUTSIDE AIR KIT MODEL AK4 AK4F Install...

Page 15: ...RTS See Pages 17 19 for a complete replacement parts list Use only parts supplied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following information 1 The model number of the appliance 2 The serial number of the appliance 3 The part number 4 Th...

Page 16: ...039 Model PT32 32 Black Cat No F1040 Model PT32B 32 Brushed Brass Cat No F1041 Model PT32P 32 Platinum Cat No F1042 Model PT36 36 Black Cat No F1043 Model PT36B 36 Brushed Brass Cat No F1044 Model PT36P 36 Platinum Cat No F1045 Model PT42 42 Black Cat No F1046 Model PT42B 42 Brushed Brass Cat No F1047 Model PT42P 42 Platinum VENT FREE GAS LOGS Please visit Astria us com for specific models sizing ...

Page 17: ...87 VALIANT36ZP3 F0388 QTY 1 J3957 Left Refractory Stacked White 1 J5946 Left Refractory Herringbone White 1 2 J3967 Rear Refractory Stacked White 1 J5942 Rear Refractory Herringbone White 1 3 J3962 Right Refractory Stacked White 1 J5944 Right Refractory Herringbone White 1 4 J6743 Bottom Refractory White 1 KEY NO Cat No DESCRIPTION VALIANT42ZP2 F0389 VALIANT42ZP3 F0390 QTY 1 J4065 Left Refractory ...

Page 18: ...2 3 5 4 6 7 22 8 9 10 11 12 19 21 19 18 16 15 13 14 Cat No Model Interior F0385 Valiant32ZP2 White Stack F0386 Valiant32ZP3 White Herringbone F0387 Valiant36ZP2 White Stack F0388 Valiant36ZP3 White Herringbone F0389 Valiant42ZP2 White Stack F0390 Valiant42ZP3 White Herringbone ...

Page 19: ...J5185 Refractory Retainer 2 9 J5186 Rear Refractory Retainer 1 10 RP108413 01 Firebox Top Shield 1 11 Firebox Top 1 12 Starter Pipe Collar 1 13 Insulation Pan 1 14 Fireplace Top Insulation 1 15 Fireplace Top 1 16 J6918 Top Spacer 4 17 Fireplace Surround 1 18 J4223 Gas Conduit Left and Right Assembly 2 19 J6934 Gas Knock Out Cover 3 5 20 J4011 Gas Conduit 2 20a J6951 Gas Conduit 2 J6952 Gas Conduit...

Page 20: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ________________________________________...

Page 21: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ________________________________________...

Page 22: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ________________________________________...

Page 23: ...fire flood or acts of God b damages caused by abuse negligence misuse or unauthorized alteration or repair of the Product affecting its stability or performance The Product must be subjected to normal use The Product is designed to burn either natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive tempe...

Page 24: ...cal distributor for fireplace code information Printed in U S A 2014 Innovative Hearth Products P N 126691 01 Rev B 06 2017 1508 Elm Hill Pike Suite 108 Nashville TN 37210 Astria us com Record the following important information about your appliance Appliance model number Appliance serial number Date appliance was Installed Type of gas appliance uses Dealer name P126691 01 ...

Reviews: