16
5.3 Starting the pump
1.
Press the start button on the machine or system where the pump is connected.
2.
Ensure that the pump starts; rotation of the motor, dispensing of the grease
and pressurised piping indicate that the pump is actually working.
3.
To change the pressure valve, act on the by-pass valve adjustment screw (see
Sect. 3.5). Turn clockwise to increase or anticlockwise to decrease the pressure
(see adjacent figure);
The pump is intended to feed two lines.
See sections 3.3 and 3.4 for the pump technical data.
5.4 Stopping the pump
Stopping the pump depends directly on the system where it is installed.
+
-