15
5. Operating instructions
ATTENTION
Use gloves and eye protection as required by the oil or grease lubricant safety data sheet.
DANGER
Never ignore health hazards and always follow sanitary regulations.
Before using the MINISUMO II pump, some preliminary checks must be carried out:
Check the integrity of the pump.
Ensure that the pump is at operating temperature and that the piping is free of any air bubbles.
Ensure that the electrical connection has been carried out correctly.
With the pump started, ensure that the electric motor rotation direction matches the arrow on the motor’s
protective casing. If it turns in the opposite direction, reconnect as indicated on the electrical diagram attached to
the motor.
The unit can be opened and repaired only by specialized personnel.
5.1 Preliminary procedures
5.1.1 Filling the reservoir with grease
To fill the pump reservoir with grease, proceed as follows:
1)
Unscrew the cap using an appropriate wrench;
2)
Using the ½” fitting, introduce grease into the reservoir.
The reservoir must be filled until reaching the maximum level. This level is signalled by the rising of the level rod
or, if present, by the laser level probe (optional).
3)
Screw the cap back on.
5.2