background image

10 

11.2. OPTIONAL

 

 

Equipment

 

Description 

Variant

 

P. No. 

Oil conversion 

Min/max oil level float kit 30 Kg (66lb)  

Min/max oil level float kit 100 Kg (220lb)  

Filling plug with filter 

 

0295150 

0295160 

3130138 

Terminal Box bracket 

Bracket for installing a terminal wiring box onto the base pallet 

 

3044455 

Terminal  

Terminal box 

 

0291655 

Electrical control box Bracket 

Bracket for installing a control box onto the base pallet 

 

3044456 

Metal pallet 

Metal Pallet used as the base of the packaging and also for 

installation of the pump. 

 

0297150 

 

11.3. SPARE PARTS 

 

Spare part description

 

Variant 

P.No.

 

Motors 

3Ph - 0,75 Kw IE3- 230

Δ

/400Y  50Hz  

                              280

Δ

/480Y  60Hz 

 

3301081 

3Ph UL and CSA  - 0,75 Kw IE3- 230

Δ

/400Y  50Hz  

                              - 280

Δ

/480Y  60Hz  

 

3301528 

Reducer  i=40 

 

3301608 

Maximum mechanical level kit meccanico 30 e 100 Kg (grasso) 

 

0295100 

Laser probe assembly 30÷100 Kg  - 24V cc Out NO e NC (1 threshold) 

 

0295131 

Laser level kit 24V cc Out 4÷20mA/2 NO (4 thresholds) – 30 Kg 

VAR2 

 

0295130 

Laser level kit 24V cc Out 4÷20mA/2 NO (4 thresholds) – 100 Kg 

VAR3 

Minimum level kit (250V AC) 30 kg (grease) 

 

0295121 

Minimum level kit (250V AC) 100 kg (grease) 

 

0295122 

Grease loading filter  

 

0295009 

By-pass  

 

0234815 

Pressure gauge  0 - 600 Bar 

 

3292171 

Pumping 

 

0296080C 

Metal pallet 

 

0297150 

 

 

0295130 

0295131 

0295100 

0295009 

0296080C 

3292171 

0234815 

3190485 

0297155 

Summary of Contents for 2451011

Page 1: ...NENTS 6 UNPACKING AND INSTALLING 7 OPERATING INSTRUCTIONS 8 TROUBLESHOOTING 9 MAINTENANCE PROCEDURES 10 DISPOSAL 11 ORDERING INFORMATION 12 DIMENSIONS 13 HANDLING AND TRANSPORTATION 14 PRECAUTIONS 15...

Page 2: ...type of distribution can be altered This construction technique is essentially based on the following modules Electric motor Pump body with integrated reducer Two pumping elements Reservoir Valves and...

Page 3: ...Kg reservoir 100 Kg ELECTRICAL CHARACTERISTICS Motor power supply 230 400V 5 50Hz 280 480V 5 60Hz Rated motor power 0 75 Kw Motor degree of protection IP 55 Minimum level Laser grease floating Oil Ma...

Page 4: ...sente di garantire un ottima tenuta del sistema alle alte pressioni di funzionamento pressione max di 400 bar Pumping elements are mounted on the pump casing without the need to disconnect the line pi...

Page 5: ...vel reserve and the maximum level which allows the automatic refilling of the tank to be halted For connections see paragraph 7 3 4 5 1 3 3 Maximum visual floating level for oil grease The phase that...

Page 6: ...ds or in a particularly aggressive or explosive inflammable environment if not previously prepared for that purpose by the supplier Use safety gloves or glasses as specified in the safety sheet for th...

Page 7: ...e for calibrating the laser probe 24V cc Out 4 20mA 2 NO 4 thresholds The laser probe possesses a representative and programming display mounted on board It is possible to operate in analogue mode wit...

Page 8: ...3190489 No signal indicating minimum level when there is no lubricant in the tank Incorrect adjustment of minimum level Check the correct functioning of the level probe in the following way Dismantle...

Page 9: ...74 56 UL and NEMA standard 230 460V 60 Hz On request 80 Pneumatic motor 3301539 95 Inverter NOT PRESENT 0 4 3 Valve Electromagnetic 24 V DC 0083550 1 4 2 Electromagnetic inverter 24 V DC 0083560 2 4 2...

Page 10: ...TS Spare part description Variant P No Motors 3Ph 0 75 Kw IE3 230 400Y 50Hz 280 480Y 60Hz 3301081 3Ph UL and CSA 0 75 Kw IE3 230 400Y 50Hz 280 480Y 60Hz 3301528 Reducer i 40 3301608 Maximum mechanical...

Page 11: ...12 DIMENSIONS 30 Kg 100 Kg mm in mm in A 533 5 21 983 38 7 B 1084 42 67 1534 60 39 C 984 38 74 1434 56 45 D 313 12 32 413 16 25...

Page 12: ...lectrical power supply and making sure that no one can reconnect it during the operation All the installed equipment electric and electronic tanks and basic structures must be connected to the ground...

Page 13: ...splash consequently this operation must be carried out using appropriate individual protective devices contact with oil see instructions for using appropriate individual protective devices DPI Use of...

Reviews: