6. UNPACKING AND INSTALLATION 

6.1 UNPACKING 

Once a suitable installation position has been identified, unpack the product and prepare for installation. It is important to 

inspect the product to ensure that there has been no damage during transportation. The packaging material used does not 

require any special disposal procedures. You should refer to you regional requirements. 

 

6.2  INSTALLATION

  

No pump assembly operations are envisaged. The pump is fixed on a metal pallet, which allows safe handling using a 

transpallet or forklift truck.  This pallet has been designed so that it can be installed in the installation, being 

equipped with 4 (four) holes of Ø 14 mm suitable for fixing to the floor. Provide adequate space (as shown on the 

installation diagram) to avoid abnormal posture or possible impact. Then, as described previously, the pump must be 

connected hydraulically to the machine and then connected to the control panel. 

 

7. OPERATING INSTRUCTIONS 

 

7.1 START-UP OF THE PUMP

 

Before using the product, a few preliminary checks must be performed: 

 

Check the integrity of the supply cable and the unit prior to use; 

 

If the supply cable or the unit is damaged, do not start up the system! 

 

Replace the damaged supply cable with a new one; 

 

The unit can be opened and repaired only by specialist personnel; 

 

In order to prevent the danger of electrocution due to direct or indirect contact with live parts the electric supply line must 

be adequately protected by an appropriate magnetothermal differential switch with threshold of intervention of 0.03 

ampere and max intervention time of 1 second; 

 

 

 

 

It is prohibited to use the pump if submersed in fluids or in a particularly aggressive or explosive/inflammable environment if 

not previously prepared for that purpose by the supplier. 

 

Use safety gloves or glasses as specified in the safety sheet for the lubricating oil 

 

Do NOT use lubricants which are aggressive towards NBR gaskets, and if in doubt consult the Dropsa SpA technical office 

which will supply a detailed list of the recommended oils; 

 

Do not ignore dangers to health and comply with health and safety regulations; 

 

 

 

 

 

 

 

Check the integrity of the pump. 

 

Check that the pump is at working temperature and that there are no air pockets in the pipes. 

 

Check that the electric connection has been carried out correctly. 

 

Once the pump has started, check that the direction of rotation of the electric motor is as indicated by the arrow on the 

motor's protective casing; if it rotates backward; reconnect it as shown in the wiring diagram provided with the motor. 

 

7.2 

INSTRUCTIONS FOR USE

  

Press the start button on the machine to which the SUMO II pump is connected. 

1)

 

Check pump start-up. 

2)

 

To change the pressure value, turn the by-pass adjustment screw (see Chap. 5). Turn it clockwise to increase the pressure 

or counter clockwise to decrease it; 

3)

 

Check that the machine is adequately lubricated (if there are still some doubts about its correct functioning you can contact 

the Dropsa S.p.A Technical Office and request a test procedure). 

 

The interruption power of the switch must be 

 10 kA and rated current In 

=

 6 A. 

 

 

Warning!  All the electric components must be earthed.  This applies to both the electric components, and to the control 

devices. To this end make sure that the earth wire is connected correctly. For safety reasons the earth conductor must be 

approximately 100 mm longer than the phase conductors. If the cable is accidentally removed, the earth terminal must be the 

last one to be removed. 

 

 

Summary of Contents for 2451011

Page 1: ...NENTS 6 UNPACKING AND INSTALLING 7 OPERATING INSTRUCTIONS 8 TROUBLESHOOTING 9 MAINTENANCE PROCEDURES 10 DISPOSAL 11 ORDERING INFORMATION 12 DIMENSIONS 13 HANDLING AND TRANSPORTATION 14 PRECAUTIONS 15...

Page 2: ...type of distribution can be altered This construction technique is essentially based on the following modules Electric motor Pump body with integrated reducer Two pumping elements Reservoir Valves and...

Page 3: ...Kg reservoir 100 Kg ELECTRICAL CHARACTERISTICS Motor power supply 230 400V 5 50Hz 280 480V 5 60Hz Rated motor power 0 75 Kw Motor degree of protection IP 55 Minimum level Laser grease floating Oil Ma...

Page 4: ...sente di garantire un ottima tenuta del sistema alle alte pressioni di funzionamento pressione max di 400 bar Pumping elements are mounted on the pump casing without the need to disconnect the line pi...

Page 5: ...vel reserve and the maximum level which allows the automatic refilling of the tank to be halted For connections see paragraph 7 3 4 5 1 3 3 Maximum visual floating level for oil grease The phase that...

Page 6: ...ds or in a particularly aggressive or explosive inflammable environment if not previously prepared for that purpose by the supplier Use safety gloves or glasses as specified in the safety sheet for th...

Page 7: ...e for calibrating the laser probe 24V cc Out 4 20mA 2 NO 4 thresholds The laser probe possesses a representative and programming display mounted on board It is possible to operate in analogue mode wit...

Page 8: ...3190489 No signal indicating minimum level when there is no lubricant in the tank Incorrect adjustment of minimum level Check the correct functioning of the level probe in the following way Dismantle...

Page 9: ...74 56 UL and NEMA standard 230 460V 60 Hz On request 80 Pneumatic motor 3301539 95 Inverter NOT PRESENT 0 4 3 Valve Electromagnetic 24 V DC 0083550 1 4 2 Electromagnetic inverter 24 V DC 0083560 2 4 2...

Page 10: ...TS Spare part description Variant P No Motors 3Ph 0 75 Kw IE3 230 400Y 50Hz 280 480Y 60Hz 3301081 3Ph UL and CSA 0 75 Kw IE3 230 400Y 50Hz 280 480Y 60Hz 3301528 Reducer i 40 3301608 Maximum mechanical...

Page 11: ...12 DIMENSIONS 30 Kg 100 Kg mm in mm in A 533 5 21 983 38 7 B 1084 42 67 1534 60 39 C 984 38 74 1434 56 45 D 313 12 32 413 16 25...

Page 12: ...lectrical power supply and making sure that no one can reconnect it during the operation All the installed equipment electric and electronic tanks and basic structures must be connected to the ground...

Page 13: ...splash consequently this operation must be carried out using appropriate individual protective devices contact with oil see instructions for using appropriate individual protective devices DPI Use of...

Reviews: