LVC-III—AeroLift 25 

Wiring Diagram

To 110 -120V AC Line

Location of key 
operated 0n-off
switch if furnished.

Safety Up Switch

White (Common)

Red (Up)

Black ( Down)

Green (Ground)

MOTOR

Dashed Wiring 
By electrician.

N

Up

Dn

3 Button Wall Switch 
DOWN
COM 
UP

White-Neutral (Common) to lift & 110-120V AC

Red-to lift (directional)

Brown-to lift (directional)

Yellow-to 110-120V AC

Black-to 110-120V AC

Green-Ground

Eye Port 

for IR Eye, RF Receiver or LED

Switch. If more than one of these three is
used with one LVC-III, a splitter is required.

Aux Port 

for connecting additional LVC-III modules 

(up to six total-connect from Aux to Eye).

Low voltage 
wiring by others.

LVC-III—AeroLift 50/150 

Wiring Diagram

To 110 -120V AC Line

Location of key 
operated 0n-off
switch if furnished.

Safety Up Switches

White (Common)

Black (Up)

Red ( Down)

Green (Ground)

MOTOR

Dashed Wiring 
By electrician.

N

Up

Dn

3 Button Wall Switch 
DOWN - Black
COM - White
UP - Red

White-Neutral (Common) to lift & 110-120V AC

Red-to lift (directional)

Brown-to lift (directional)

Yellow-to 110-120V AC

Black-to 110-120V AC

Green-Ground

Eye Port 

for IR Eye, RF Receiver or LED

Switch. If more than one of these three is
used with one LVC-III, a splitter is required.

Aux Port 

for connecting additional LVC-III modules 

(up to six total-connect from Aux to Eye).

Low voltage
wiring by others.

www.draperinc.com

(765) 987-7999

Summary of Contents for LVC-III

Page 1: ...III modules up to six connect from Aux to Eye Low voltage wiring by others YW PCB 1 T 1 110 VAC SUPPLY PROJECTOR OUTLET Wiring by Electrician GND N 50 60 HZ L1 GN BK WH F3 CB1B 8 BK 10 9 RD BK BK BK 6 7 4 5 3 2 1 F1 F2 YW YW C2 BK RD BE YW D1 BK DOWN ALL WIRES 18 AWG UNLESS OTHERWISE SPECIFIED BE BK 10 9 8 7 6 5 4 3 2 1 CB1A BK WH BK BE C1 BK RD BE BE BE WH DOWN LIMIT SW UP LIMIT SW RD RD BE BE BE...

Page 2: ...onal LVC III modules up to six total connect from Aux to Eye Low voltage wiring by others LVC III AeroLift 50 150 Wiring Diagram To 110 120V AC Line Location of key operated 0n off switch if furnished Safety Up Switches White Common Black Up Red Down Green Ground MOTOR Dashed Wiring By electrician N Up Dn 3 Button Wall Switch DOWN Black COM White UP Red White Neutral Common to lift 110 120V AC Red...

Page 3: ...k Black White 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Black Black Black Black Black Red Red White White White Green Receptacle Limit Switch LS1 NO Down Travel Limit Switch LS2 NC Up Travel Limit Switch LS3 NC Black Red 1 2 3 4 5 AC Current Sensor Yellow These can be omitted if LVC is mounted remotely 3 Button Wall Switch DOWN Black COM White UP Red Green Ground Eye Port for IR Eye RF Receiver or LE...

Page 4: ...h DOWN Black COM White UP Red Wall Switch A maximum of six 6 LVC III modules can be linked together Low voltage wiring by others 3 Button Wall Switch DOWN Black COM White UP Red White Neutral Common to screen 110 120V AC Red to screen directional Brown to screen directional Yellow to 110 120V AC Black to 110 120V AC Green Ground Eye Port for IR Eye RF Receiver or LED Switch For more than one of th...

Reviews: