d)  watch  the  diode  in  charger 

– change in colour from red to green means proper and full 

charge. 

Charging a completely discharged battery takes ca. 2 hours 30 minutes. After fully charging the 

battery the charger automatically stops charging. 

 

Warning 

It is forbidden to conduct repair of the charger by the user and device disassembly by 
unauthorized personnel. 
The battery for the device should be charged only with a charger designed for it. 

Do not use the charger in damp or wet places. It may result in damage of the device. 

Before using the charger always make sure that its main elements are not damaged. 

In case of finding any damages, immediately disconnect the device from power source and 
replace the faulty element with a new one. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Precautions when using Li-Ion battery pack 

  Do not disassemble battery packs that make an integrated whole. 

  Do not throw battery packs into fire and heat them. 

  Do not exert physical force on packs or throw them. 

  In situation when an electrolyte discharge from pack can be observed, you should immediately 

cease using it. 

 

Do not allow to let the liquid enter the pack’s inside, which may result in sudden temperature 
rise of battery and danger of electric shock. 

  Do  not  leave  the  battery  pack  in  high  ambient  temperature  e.g.  inside  the  car  directly  in  the 

sunlight,  near  heat  sources.  Not  observing  these  rules  may  result  in  an  electrolyte  leakage 
from the battery and its damage or shortening its life span. 

 

The battery should be charged in an ambient temperature between 0 °C and 40 °C.  Charging 
battery  in  the  ambient  temperature  different  than  set  range  may  result  in  danger  and 
permanent damage to the pack. 

  In  the  case  of  problems  with  charging  after  long  time  of  usage  (ca.  500  cycles)  you  should 

replace the battery pack with a new one. 

  Used battery packs should be subject to recycling according to relevant regulations. 

 

Summary of Contents for iScan

Page 1: ...portable diagnostic ultrasound scanner with an electronic probe instruction manual 25 04 2017r ISO 9001...

Page 2: ...d 7 V FUNCTION KEYS DESCRIPTION Left hand keyboard 8 VI MENU STRUCTURE 10 VIII PREPARATION TO WORK 18 IX EXAMINATION OF ANIMALS 18 X CHARGING BATTERIES 18 XI DEVICE AND PROBE MAINTENANCE 20 XII OPERAT...

Page 3: ...es tendons and eyeballs and in case of every examination where the electronic linear probe can be used Read this instruction manual carefully before starting the ultrasound scanner It will guarantee s...

Page 4: ...al III CONSTRUCTION The device comprises of three main elements 1 Housing with membrane keyboard 5 screen with LED illumination and port for communication with a PC 2 Ultrasound probe 3 External packa...

Page 5: ...ation the package is mounted with a special strap at the bottom of the device Photo 3 Battery life cycle is estimated at 500 charging cycles Thanks to the use of advanced high capacity batteries it is...

Page 6: ...every time when you turn on scanner It remembers last setting all the time To switch back to the main display press and hold OK button for 4 seconds Then you can disconnect goggles from the scanner 3...

Page 7: ...on confirming settings 2 Confirming marker position when measuring On off switch Exit menu Navigation keys scrolling through menu and set of parameter values Cineloop function automatic rewind fast fo...

Page 8: ...n confirming settings 2 Confirming marker position when measuring On off switch Exit menu Navigation keys scrolling through menu and set of parameter values Cineloop function automatic rewind fast for...

Page 9: ...wska niki poziomu wzmocnie wska nik stanu baterii poziom zoom stan pracy aktualna data g eboko skanowania data zapisu cine poziom focus cz stotliwo g owicy linijka direction set for displayed image R...

Page 10: ...order to go from option to option in menu you can use navigation buttons chosen option will be marked with a green background To confirm chosen menu option use the OK button To exit chosen menu optio...

Page 11: ...buttons Press OK and the image will appear on the display Cine Option of saving video sequences to memory to show them on screen load 1 Save Cine Option of saving Cine loop After freezing the image y...

Page 12: ...ments of the test object and to determine the age of the fetus After entering the Measurements option and pressing G2 button an advanced measurement menu is displayed Select options with arrow buttons...

Page 13: ...eeze button in this option an active image stops and by using ESC button it can be moved to the left side of the screen Pressing the Freeze button again will activate the image on the right hand side...

Page 14: ...ight side After choosing this option the user can change the shown image to side reflecting the anatomical structure of the animal It is important in the case of rectal examination by left handed or r...

Page 15: ...able desc will appear The user can choose YES or NO using navigation buttons If the user change this setting to YES then describing of the image will be possible during saving them to the memory with...

Page 16: ...he ruler icon there is a red triangle which can be moved with navigational buttons at the image height which we want to sharpen This function is designed to sharpen the image of the examined object as...

Page 17: ...confirm its position by pressing OK a new green marker appears and simultaneously under the image there will be a message about measuring state distance between cursors e g L0 12mm This result will be...

Page 18: ...experience 3 During the examination the keyboard is used to set the best working parametres in given conditions The device remembers last used settings To achieve the optimal image of the examined ob...

Page 19: ...integrated whole Do not throw battery packs into fire and heat them Do not exert physical force on packs or throw them In situation when an electrolyte discharge from pack can be observed you should i...

Page 20: ...be cleaned with running not hot water or immersed in water with an addition of detergent or properly dissolved disinfectant Do not use highly concentrated agents and scrubbing agents During cleaning a...

Page 21: ...on control membrane keyboard Cineloop image sequence 256 frames ca 20 seconds image memory 200 images with date index No and description Cine memory 50 cine loops with date index No and description tr...

Page 22: ...Owocowa 17 10 860 Olsztyn and returning a functioning device to the user at the manufacturer s expense Guarantee does not include mechanical damage damage resulting from improper use storage and repa...

Page 23: ...23 Software installation manual and image transmission to the PC...

Page 24: ...omputer install software first Run installation programme setup exe from the CD attached to the device The programme will guide you through the software installation process After starting the program...

Page 25: ...to the driver folder Driver folder can be found in the DRIVER file Choose Next to continue You have to choose a folder in which the programme shortcut will be placed It can be found later for example...

Page 26: ...inue Installation programme informs about the proper course of installation Choose Finish to successfully finish the installation After installation of iScan cine data transmission programme the compu...

Page 27: ...ar Press Get iScan images to transmit images Press Get iScan cines to transmit cine loop 3 On the computer s screen a window appears with a possibility to choose a place to download images to the comp...

Page 28: ...ss To stop transmission click the Break button on the computer screen A window with message Finish on the computer s screen appears to confirm successful action Images and cine loops can be deleted fr...

Page 29: ...e product Caution read the instruction manual carefully Product manufacturer s name and address Recycle separately with other household waste according to the Commission s Directive UE 93 86 EEC or lo...

Reviews: