Drain-All 870100 Installation Manual Download Page 7

Page 7

MODEL 1700

TM

PARTS & MATERIALS OF CONSTRUCTION

CODE

PART #

ITEM

DESCRIPTION/REMARKS

Qty

1

302500

Screw, Self-Tapping, #10 x 5/8" L

Zinc Plated Steel

1

2

302806

Name Plate

Aluminum

1

3

300600

Push to Test Button, 0.380" Dia x 1.265" L

Brass 

1

4

300700

Control Air Filter Assembly, 1/4" NPT

Aluminum Head, Polycarbonate Bowl, Push Drain

1

5

300800

Hex Nipple, 1/4" NPT, 1-1/8" L

Brass 

1

6

170100

Head, 7"x7"x1-1/2", 0.150" Groove

6061-T6 Aluminum

1

7

301000

Elbow Fitting, 1/8" NPT - 1/4" Tube

Brass 

2

8

300301

Cylinder Mount Kit

Includes: 

1

      (2) Brackets-Electroless Nickel Plated 
      (4) Screws-Zinc Plated Steel
      (1) Mount Pin-Electroless Nickel Plated
      (1) Cotter Pin-Stainless Steel

9

350352

Control Air Tube, 1/4" Dia x 7" L

Nylon

1

10

302210

Valve Stem O-ring, 0.235" ID x 0.069" T

Viton, Brown

1

11

100730

Valve Stem, 0.363" Dia x  2.235" L

O-ring Seal, 6061-T6 Aluminum

1

12

400100

Inner Magnet, 0.895" Dia x 1.450" L

Ceramic with Viton Ends and Covering

1

13

302215

Center Tube O-ring, 1.096" ID x 0.069" T

Viton, Brown

1

14

200170

Center Tube, 1.150" Dia x 4.500" L

O-ring Seal, 6061-T6 Aluminum

1

15

302270

Hex Bolt, 1/2" - 13 x 10" L

Zinc Plated Steel

4

16

300314

Pneumatic Cylinder, 2" Dia

40 - 130 PSI, Stainless Steel Body and Rod, Aluminum Ends

1

17

100480

Float

Polyurethane, Bullet Shaped

1

18

302200

Sleeve O-ring, 5.519" ID x 0.137" T

Viton, Brown

2

19

100300

Sleeve, 6" ID x 7" L x .125" T

Epoxy Fiberglass, Translucent

1

20

301570

Washer, 1/2" SAE

Zinc Plated Steel

4

21

300303

Clevis and Pin Kit

Includes: 

1

      (1) Clevis-Electroless Nickel Plated 
      (1) Clevis Pin-Electroless Nickel Plated
      (2) Washers-Zinc Plated Steel
      (1) Cotter Pin-Stainless Steel

22

100800

Control Lever, 1.625" L x 0.500" W x 0.125" T

Stainless Steel for 1/2" NPT Ball Valve

1

23

170200

Base, 7"x7"x1-1/2", 1/2" NPT, 0.150" Groove

6061-T6 Aluminum

1

24

300900

Hex Nipple, 1/2" NPT, 1-1/2" L

Brass 

1

25

300205

Heavy Duty Ball Valve, 1/2" NPT

Double O-ring Viton Stem Seals, Nickel Plated Brass

1

26

302370

Coupling Nut, 1/2" - 13 x 1-3/4" L

Zinc Plated Steel

4

27

301130

Installation Kit

Includes: 

1

28

      (2) Needle Valve-Brass 

29

      (1) Straight Fitting-Brass

30

      (1) Elbow Fitting-Brass

31

      (1) 24' - 1/4" Dia LDPE Tube

022802 Model 1700-IG

Summary of Contents for 870100

Page 1: ...tents 4 444 217 4 562 855 4 574 829 5 004 004 5 014 735 5 983 919 Model 1700TM TM Model 1700 TM Part Number 870100 Max Liquid Temp ºF ºC 170 76 7 Max Liquid Pressure PSIG BARG 170 11 7 Control Air Min PSIG BARG 40 2 8 Control Air Max PSIG BARG 130 9 0 Ht cm 11 27 9 Width cm 9 1 4 23 5 Depth Inlet BV cm 10 1 2 26 7 Inlet Outlet NPT 1 2 Control Air NPT 1 4 Balance Line NPT 1 8 Max Capacity GPM l h 3...

Page 2: ...n follow the start up instructions for adjusting the opening of the balance line needle valve There will be very little air loss to atmosphere NO MANIFOLDS There cannot be multiple system drains through a manifold to one Model 1700TM This will not work because all system drains will not be of the same pressure Therefore the liquid from the higher pressure drain lines will bypass the Model 1700TM a...

Page 3: ...he Model 1700TM must be below the bottom of the vessel being drained 7 Once properly installed no further adjustments to the Model 1700TM are nec essary The Model 1700TM is fully auto matic discharging on demand as needed when liquid accumulates TROUBLESHOOTING 1 Water does not enter A Balance line isolation shutoff valve is closed which does not allow liquid to enter the Model 1700TM Solution Adj...

Page 4: ...Page 4 MODEL 1700TM DIMENSIONAL PRINT 022802 Model 1700 IG ...

Page 5: ... valve starting the discharge of accumulated liquid When the correct amount of liquid has been discharged leaving a liquid seal in the reservoir the float has been lowered to a point where the float magnet is below the center tube magnet In this position the float magnet repels the center tube magnet back upward against the valve stem orifice which seals off the control air flow to the actuating c...

Page 6: ...Page 6 MODEL 1700TM COMPONENT PARTS DRAWING 022802 Model 1700 IG ...

Page 7: ...ID x 0 069 T Viton Brown 1 14 200170 Center Tube 1 150 Dia x 4 500 L O ring Seal 6061 T6 Aluminum 1 15 302270 Hex Bolt 1 2 13 x 10 L Zinc Plated Steel 4 16 300314 Pneumatic Cylinder 2 Dia 40 130 PSI Stainless Steel Body and Rod Aluminum Ends 1 17 100480 Float Polyurethane Bullet Shaped 1 18 302200 Sleeve O ring 5 519 ID x 0 137 T Viton Brown 2 19 100300 Sleeve 6 ID x 7 L x 125 T Epoxy Fiberglass T...

Page 8: ...e control air line be hooked together via a tee connection No Do not do this Each of these air lines has its own specific purpose and should never be tied together The con trol air should be the cleanest driest air available since it supplies air to the con trol circuit to operate the pneumatic actu ating cylinder which functions best and lasts longer if clean dry air is used The balance line allo...

Page 9: ...ion With the addition of a Drain All cycle counter on the Drain All unit it is easy to track how much liquid is produced over any period of time This is particularly important for benchmarking system equipment performance and per forming trend analysis For example it is essential to know the quantity of liquid produced by a compressed air system to properly size oil water separators The counter co...

Page 10: ...ups The Model 1700TM center fore ground in the photo above is Drain All Inc s flagship product used in facilities around the world to remove liquid from compressed air system applications In addition to the Model 1700TM there are other Product Groups that can include different models for specific require ments There are also situations where specific applications require the use of compo nents mat...

Page 11: ...at Drain All Inc s election and cost to the repair or replacement of the defective part that does not comply with any applicable warran ty and shall in no event exceed the original purchase price of the unit Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limi tation may not apply to purchaser All claims under this warranty should be made by...

Page 12: ...rst four applications above the balance line is connected back to the vessel that is producing the condensate The pres sure on the incoming condensate to the trap and the pressure in the balance line are the same and the trap is filling by gravity For this method the top of the trap must be below the bottom of the vessel being drained Method 2 Connect the balance line port to the head er pipe leav...

Reviews: