Drain-All 870100 Installation Manual Download Page 10

TM

Drain-All, Inc. is an  engineering, manu-
facturing and marketing company with
an ISO 9002 certified quality system.
Drain-All, Inc. provides unique, high
quality, reliable product solutions for
draining and moving liquids such as: (1)
condensate removal from compressed air
systems, (2) oils and lubricants from
manufacturing, processing or test equip-
ment, and (3) liquids from atmospheric
and vacuum systems. These patented
devices are backed by an excellent war-
ranty. 

The Drain-All, Inc. technical support
team is available to assist customers in
applying the wide array of Drain-All,
Inc. products, options and accessories in
developing engineered solutions for liq-
uid drainage problems. 

Shown in the photo above are a few of
Drain-All, Inc’s standard Product
Groups. The Model 1700

TM

(center fore-

ground in the photo above) is Drain-All,
Inc’s flagship product used in facilities
around the world to remove liquid from
compressed air system applications.

In addition to the Model 1700

TM

there are

other Product Groups that can include
different models for specific require-
ments. 

There are also situations where specific
applications require the use of compo-
nents, materials of construction and/or
design elements from more than one
Product Group. These “Special Products”
can be quoted upon request. Drain-All,
Inc. will evaluate your application
requirements and provide a cost for an
appropriate product solution.

Visit Drain-All, Inc. on the Internet at: 

Drain-All.com

At the web site you can find out about the
specifications for many of Drain-All’s
standard models, the technology about
how they work, and how to submit
inquiries about specific application
requirements. 

Page 10

022802 Model 1700-IG

TM

TM

TM

TM

TM

TM

TM

Summary of Contents for 870100

Page 1: ...tents 4 444 217 4 562 855 4 574 829 5 004 004 5 014 735 5 983 919 Model 1700TM TM Model 1700 TM Part Number 870100 Max Liquid Temp ºF ºC 170 76 7 Max Liquid Pressure PSIG BARG 170 11 7 Control Air Min PSIG BARG 40 2 8 Control Air Max PSIG BARG 130 9 0 Ht cm 11 27 9 Width cm 9 1 4 23 5 Depth Inlet BV cm 10 1 2 26 7 Inlet Outlet NPT 1 2 Control Air NPT 1 4 Balance Line NPT 1 8 Max Capacity GPM l h 3...

Page 2: ...n follow the start up instructions for adjusting the opening of the balance line needle valve There will be very little air loss to atmosphere NO MANIFOLDS There cannot be multiple system drains through a manifold to one Model 1700TM This will not work because all system drains will not be of the same pressure Therefore the liquid from the higher pressure drain lines will bypass the Model 1700TM a...

Page 3: ...he Model 1700TM must be below the bottom of the vessel being drained 7 Once properly installed no further adjustments to the Model 1700TM are nec essary The Model 1700TM is fully auto matic discharging on demand as needed when liquid accumulates TROUBLESHOOTING 1 Water does not enter A Balance line isolation shutoff valve is closed which does not allow liquid to enter the Model 1700TM Solution Adj...

Page 4: ...Page 4 MODEL 1700TM DIMENSIONAL PRINT 022802 Model 1700 IG ...

Page 5: ... valve starting the discharge of accumulated liquid When the correct amount of liquid has been discharged leaving a liquid seal in the reservoir the float has been lowered to a point where the float magnet is below the center tube magnet In this position the float magnet repels the center tube magnet back upward against the valve stem orifice which seals off the control air flow to the actuating c...

Page 6: ...Page 6 MODEL 1700TM COMPONENT PARTS DRAWING 022802 Model 1700 IG ...

Page 7: ...ID x 0 069 T Viton Brown 1 14 200170 Center Tube 1 150 Dia x 4 500 L O ring Seal 6061 T6 Aluminum 1 15 302270 Hex Bolt 1 2 13 x 10 L Zinc Plated Steel 4 16 300314 Pneumatic Cylinder 2 Dia 40 130 PSI Stainless Steel Body and Rod Aluminum Ends 1 17 100480 Float Polyurethane Bullet Shaped 1 18 302200 Sleeve O ring 5 519 ID x 0 137 T Viton Brown 2 19 100300 Sleeve 6 ID x 7 L x 125 T Epoxy Fiberglass T...

Page 8: ...e control air line be hooked together via a tee connection No Do not do this Each of these air lines has its own specific purpose and should never be tied together The con trol air should be the cleanest driest air available since it supplies air to the con trol circuit to operate the pneumatic actu ating cylinder which functions best and lasts longer if clean dry air is used The balance line allo...

Page 9: ...ion With the addition of a Drain All cycle counter on the Drain All unit it is easy to track how much liquid is produced over any period of time This is particularly important for benchmarking system equipment performance and per forming trend analysis For example it is essential to know the quantity of liquid produced by a compressed air system to properly size oil water separators The counter co...

Page 10: ...ups The Model 1700TM center fore ground in the photo above is Drain All Inc s flagship product used in facilities around the world to remove liquid from compressed air system applications In addition to the Model 1700TM there are other Product Groups that can include different models for specific require ments There are also situations where specific applications require the use of compo nents mat...

Page 11: ...at Drain All Inc s election and cost to the repair or replacement of the defective part that does not comply with any applicable warran ty and shall in no event exceed the original purchase price of the unit Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limi tation may not apply to purchaser All claims under this warranty should be made by...

Page 12: ...rst four applications above the balance line is connected back to the vessel that is producing the condensate The pres sure on the incoming condensate to the trap and the pressure in the balance line are the same and the trap is filling by gravity For this method the top of the trap must be below the bottom of the vessel being drained Method 2 Connect the balance line port to the head er pipe leav...