Before installing the Drain-All, Inc.
Model 1700

TM

, a review of the following

items will help make the right decision
regarding options which could be used to
ensure long-term maintenance free oper-
ation.

RUST AND SCALE

Even though the Drain-All, Inc. Model
1700

TM

is designed for handling rust and

scale, it is recommended that the system
be blown down after all piping is
installed and before the Model 1700

TM

is

connected to the piping. The Model
1700

TM

, with a large, smooth, liquid flow

path, easily handles contaminates in the
liquid once the system is in operation. If
there is excessive rust and scale on a con-
tinuous basis, consider using the Rust
Handler

TM

designed for compressed air

systems that have extremely heavy
amounts of rust and scale. 

CONTROL AIR & BALANCE LINE

The control air line provides air through
the sealed center tube to operate the air
cylinder. Clean dry air should be used for
this control air supply. The balance line
provides a means to handle the displaced
air from the reservoir as the liquid enters
the reservoir. The control air line and the
balance line are two separate lines which
have nothing in common with each other
and should never be connected to each
other in any way.  Do not tie them togeth-
er with a tee fitting.

CONTROL AIR

Control air pressure requirements vary by
product and must be regulated within
specifications provided in the product’s
Installation Guide. If the specified pres-
sure for control air cannot be supplied in
your application, contact your distributor
for information on control air options
offered by Drain-All, Inc. to accommo-
date your available control air pressure. 

BALANCE LINE

The balance line must have either (1)
exactly the same pressure as the vessel
being drained or (2) slightly less pressure
than the vessel being drained. 

The same pressure is achieved when the
balance line is tied back into the vessel
being drained, such as connecting the
balance line at a tee fitting on the vessel’s
pressure gage or access port.  A slightly
lower pressure may be achieved by locat-
ing the balance line connection on the air
header pipe a few feet downstream from
the vessel being drained. When hooking
the balance line to an air header, connect
it to the header prior to any other vessel
attached to the header.

If there is absolutely no place to connect
the balance line into the air system, or if
a temporary installation is to be made
while waiting for the next shutdown to tie
in the balance line, the balance line can
be vented to atmosphere. Install the nee-
dle valve that comes as a component of
the installation kit into the port on top of
the Model 1700

TM

where ''Balance Line''

is indicated. Then follow the start-up
instructions for adjusting the opening of
the balance line needle valve.  There will
be very little air loss to atmosphere. 

NO MANIFOLDS

There cannot be multiple system drains
through a manifold to one Model 1700

TM

.

This will not work because all system
drains will not be of the same pressure.
Therefore, the liquid from the higher
pressure drain lines will bypass the
Model 1700

TM

and flow backwards up the

lower pressure drains. Installing check
valves on system drains is not a solution
because pressure variations which inhibit
proper operation will still be present.
Proper installation of the balance line is
not possible with multiple drains hooked
up through a manifold.

CORROSION

There are Drain-All, Inc. products avail-
able which include corrosion resistant
coatings and materials.  If the application
environment is highly corrosive, check
these products and options to determine
if they should be specified. Also available
are Drain-All, Inc. products which handle
higher pressures and temperatures. 

INSTALLATION STEPS

1.

Prior to installing the Model 1700

TM

,

blow down the vessel being drained to
remove excessive rust, scale, and dirt
knocked loose during piping installation.

2.

Remove the Model 1700

TM

from the

box and set it in an upright position
where it will be connected. Most Drain-
All, Inc. products do not have to be
secured. Larger volume and higher pres-
sure products may require some form of
movement restraint. To ensure proper
operation in all installation layouts, the
top of the Model 1700

TM

should be lower

than the bottom of the vessel being
drained.

3.

Using 1/2” pipe, connect the vessel

being drained to the 1/2” liquid inlet on
the base of the Model 1700

TM

. Be sure to

install a shut-off valve and a bypass valve
between the vessel being drained and the
Model 1700

TM

. This will allow easy

removal of the Model 1700

TM

"on the

run" during any preventive maintenance
activities. After installing the piping,
close the inlet shut-off valve.

4.

Using 1/2” pipe, connect the Model

1700

TM

discharge outlet to a sealed drain

pipeline or enclosed/covered trough. The
discharged liquid is under pressure and
can splash back if directed downward
toward the bottom of a simple, shallow,
open trough-type floor drain. 

5.

Connect the balance line from the

Model 1700

TM

to the appropriate connect-

ing point on the vessel being drained
using the tubing and needle valve provid-
ed in the installation kit. After installing
the balance line, close the balance line
needle valve.

6. 

Using the tubing and needle valve pro-

vided in the installation kit, connect the
control air supply line to the control air
filter inlet on the Model 1700

TM

.  Always

use the cleanest and driest air possible to
ensure long term maintenance free oper-
ation.  After connecting the control air
line, close the control air needle valve.

INSTALLATION

Page 2

022802 Model 1700-IG

Summary of Contents for 870100

Page 1: ...tents 4 444 217 4 562 855 4 574 829 5 004 004 5 014 735 5 983 919 Model 1700TM TM Model 1700 TM Part Number 870100 Max Liquid Temp ºF ºC 170 76 7 Max Liquid Pressure PSIG BARG 170 11 7 Control Air Min PSIG BARG 40 2 8 Control Air Max PSIG BARG 130 9 0 Ht cm 11 27 9 Width cm 9 1 4 23 5 Depth Inlet BV cm 10 1 2 26 7 Inlet Outlet NPT 1 2 Control Air NPT 1 4 Balance Line NPT 1 8 Max Capacity GPM l h 3...

Page 2: ...n follow the start up instructions for adjusting the opening of the balance line needle valve There will be very little air loss to atmosphere NO MANIFOLDS There cannot be multiple system drains through a manifold to one Model 1700TM This will not work because all system drains will not be of the same pressure Therefore the liquid from the higher pressure drain lines will bypass the Model 1700TM a...

Page 3: ...he Model 1700TM must be below the bottom of the vessel being drained 7 Once properly installed no further adjustments to the Model 1700TM are nec essary The Model 1700TM is fully auto matic discharging on demand as needed when liquid accumulates TROUBLESHOOTING 1 Water does not enter A Balance line isolation shutoff valve is closed which does not allow liquid to enter the Model 1700TM Solution Adj...

Page 4: ...Page 4 MODEL 1700TM DIMENSIONAL PRINT 022802 Model 1700 IG ...

Page 5: ... valve starting the discharge of accumulated liquid When the correct amount of liquid has been discharged leaving a liquid seal in the reservoir the float has been lowered to a point where the float magnet is below the center tube magnet In this position the float magnet repels the center tube magnet back upward against the valve stem orifice which seals off the control air flow to the actuating c...

Page 6: ...Page 6 MODEL 1700TM COMPONENT PARTS DRAWING 022802 Model 1700 IG ...

Page 7: ...ID x 0 069 T Viton Brown 1 14 200170 Center Tube 1 150 Dia x 4 500 L O ring Seal 6061 T6 Aluminum 1 15 302270 Hex Bolt 1 2 13 x 10 L Zinc Plated Steel 4 16 300314 Pneumatic Cylinder 2 Dia 40 130 PSI Stainless Steel Body and Rod Aluminum Ends 1 17 100480 Float Polyurethane Bullet Shaped 1 18 302200 Sleeve O ring 5 519 ID x 0 137 T Viton Brown 2 19 100300 Sleeve 6 ID x 7 L x 125 T Epoxy Fiberglass T...

Page 8: ...e control air line be hooked together via a tee connection No Do not do this Each of these air lines has its own specific purpose and should never be tied together The con trol air should be the cleanest driest air available since it supplies air to the con trol circuit to operate the pneumatic actu ating cylinder which functions best and lasts longer if clean dry air is used The balance line allo...

Page 9: ...ion With the addition of a Drain All cycle counter on the Drain All unit it is easy to track how much liquid is produced over any period of time This is particularly important for benchmarking system equipment performance and per forming trend analysis For example it is essential to know the quantity of liquid produced by a compressed air system to properly size oil water separators The counter co...

Page 10: ...ups The Model 1700TM center fore ground in the photo above is Drain All Inc s flagship product used in facilities around the world to remove liquid from compressed air system applications In addition to the Model 1700TM there are other Product Groups that can include different models for specific require ments There are also situations where specific applications require the use of compo nents mat...

Page 11: ...at Drain All Inc s election and cost to the repair or replacement of the defective part that does not comply with any applicable warran ty and shall in no event exceed the original purchase price of the unit Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limi tation may not apply to purchaser All claims under this warranty should be made by...

Page 12: ...rst four applications above the balance line is connected back to the vessel that is producing the condensate The pres sure on the incoming condensate to the trap and the pressure in the balance line are the same and the trap is filling by gravity For this method the top of the trap must be below the bottom of the vessel being drained Method 2 Connect the balance line port to the head er pipe leav...

Reviews: