22 Installation
(for qualified installers only)
© Travis Industries
4140514
100-01374
Minimum Vent Pipe Shield – Used for Minimum Vent Configuration Only
The minimum vent pipe shield and side shields are required when running minimum vent configurations
(see page 27)
. The shield is shipped with the fireplace loose and must be installed as shown below.
Secure the pipe shield to the
firestop (mouting holes are
slotted to allow for leveling).
Approximately 41"
(1042mm) with no rise.
Pipe Shield
Firestop
Secure the pipe shield to the pipe
with 4 screws. Make sure shield
is level and maintains 1" (25mm)
clearance to pipe.
1" (25mm) Clearance