2 Introduction
© Travis Industries
4140514
100-01374
Overview
This manual details the installation
requirements for the 3615 HO GSR2 fireplace.
For operating and maintenance instructions,
refer to the 3615 HO GSR2 Owner's Manual
(part # 100-01375).
IAPMO-R&T
OCEANA
Gas Mark
TM
GMK10166
3615 GSR2 (Au)
V
ented Gas Fireplace Heater
T
ested to the combustion performance and construction requirements of
AS 4553-2008 Gas Space Heating
Appliances. This appliance must be installed in accordance with all local codes.
This 6015 GSR2 appliance is equipped from the factory only for use with Natural Gas and is only for use
with the type of gas indicated on the rating plate. For conversion to LP
(Propane) use a certified kit
supplied by the manufacturer
. See owner
’s manual for information on making these changes.
This appliance may be installed in an aftermarket, permanently located, manufactured (mobile) home where
not prohibited by local codes.
This vented gas fireplace heater is not for use with air filters. This appliance must be properly connected to
a venting system in accordance with the manufacturer
’s installation instructions. Use only approved
coaxial direct vent systems to vent this appliance to the exterior
. See owner
’s manual for approved brands
of venting.
W
ARNING:
Improper installation, adjustment, alteration, service or maintenance can cause injury or
property damage. Refer to the owner
’s information manual provided with this appliance. For assistance or
additional information consult a qualified installer
, service agency or the gas supplier
.
This appliance is a V
ented Gas Fireplace Heater
. Not for use with Solid Fuel.
Y
oung children should be carefully supervised at all times when they are in the same room
as the appliance.
Fireplace to adjacent wall W
ood floor beneath fireplace
Back to enclosure
77 mm 0 mm 4 mm
Base of fireplace to enclosure top Sides to enclosure Base of fireplace to a mantel
1372 mm
17 mm
See Owner
’s Manual
Minimum Clearances to Combustibles
F
AN TYPE VENTED CIRCULA
T
OR
Blower Electrical Rating: 240V
., 0.6
Amps, 50 Hz, 76 W
atts
Minimum Inlet Pressure (kPa)
Maximum Inlet Pressure (kPa)
Manifold Pressure on “HI” (kPa)
L.P
.
2.74
3.24
2.2
N.G.
1.13
1.74
1.0
Input Rate on “HI” (MJ/h)
Input Rate on “LO” (MJ/h)
Orifice Size (DMS)
L.P
.
34.82
19.1
#52
N.G.
34.82
16.5
#36
This appliance is equipped for installation 0-610 m. For altitudes above 600m, the vent configuration, orifice, or
combination of both may need to be changed. See owner
’s manual for information on making these changes.
2015
2016
2014
Feb.
Mar
.
Jan.
May
Jun.
Apr
.
Aug.
Sep.
Jul.
Nov
.
Dec.
Oct.
MANUF
ACTURE DA
TE:
4800 Harbour Pointe Blvd. SW
Mukilteo, W
A
98275
Manufactured by:
Certificate Holder:
www
.lopi.com.au
Dragon Wholesaling Pty
. Ltd.
Unit 4, 16 Lexington Drive
Bella V
ista NSW 2153
Australia
1086