Installation
(for qualified installers only)
19
© Travis Industries
4140514
100-01374
Electrical Connection
The electrical line to the grounded receptacle inside the fireplace must be installed by a qualified installer and
must meet all local codes.
Make sure the household breaker is shut off prior to working on any electrical lines.
The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of
local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.
The electrical line must be a min. 14 gauge, and supply 240 Volts, 50 Hz, and 3 Amps.
Route the electrical connection through the junction box cover plate and attach to the hookup wires pictured
below.
Caution:
Label all wires prior to disconnection when servicing controls. Wiring errors can cause
improper and dangerous operation.
Do not connect 240 VAC to the gas control valve or wiring system of this fireplace.
a
b
Left Side
Electrical
Location
(Stock)
7”
(178mm)
3.5”
(89mm)
Baseplate
Electrical
Location
7.75”
(197mm)
25.5”
(648mm)
Relocating the Electrical Line to the Baseplate
Remove the front panel (see page 16). Remove the junction box from the left side (keep the screws). Remove the cover plate
from the baseplate (keep the screws). Attach the junction box to the baseplate (make sure all wiring is kept from contacting
hot or moving components). Attach the cover plate to the left side.
Junction Box
Junction Box (from inside fireplace)
Baseplate Cover Plate
a
b
c
d
Framing Opening
a
b
a
b