Dräger G 50770 Installation Instructions & Instructions For Use Download Page 9

9

Operation

Provoz

Operation

The function of the relay module is to emit individual and 
grouped messages from the Dräger Gas Management 
Network. The sources of these signals are the following 
products:
 
— Monitor G (G 50 700, G 50 720), 
— Monitor 3G (G 50 706, G 50 726), 
— Monitor 6G (G 50 707, G 50 727), 
— Data collector base (G 50 716).

The relay module receives data from the above products 
and transmits the data via relays. An activated alarm 
message is signalled by switching the relay.

The following information is displayed on Monitor R:

— Individual messages

 

An individual message (e.g. "Pressure too high" or 
"Pressure too low") is forwarded on a relay.

— Grouped messages

 

Several messages from different data sources (combi-
ned by the data collector base and Dräger emergency 
signal) are forwarded on a single relay.

— Communication faults

 

The relay module regularly interrogates the current 
status of the data sources addressed on this module. If 
it repeatedly receives no response from a data source, 
this status – with the appropriate configuration – can be 
transmitted via a relay signal (fault relay). In this case, 
relay No. 8 is used.

Provoz

Úkolem reléového modulu je odesílat jednotlivá 
a hromadná hlášení sít

ě

 

ř

ízení plyn

ů

 Dräger (Dräger Gas 

Management Network). Zdroji t

ě

chto hlášení jsou p

ř

itom 

následující výrobky:
 
–  Monitor G (G 50 700, G 50 720), 
–  Monitor 3G (G 50 706, G 50 726), 
–  Monitor 6G (G 50 707, G 50 727), 
–  základní sb

ě

ra

č

 dat (G 50 716).

Reléový modul p

ř

ijímá údaje od uvedených produkt

ů

 

a p

ř

edává je dále prost

ř

ednictvím jednotlivých relé. 

Aktivní alarmové hlášení je signalizováno sepnutím relé.

Na Monitoru R jsou zobrazeny tyto informace:

– Jednotlivá hlášení

 

Jednotlivé hlášení (nap

ř

. "P

ř

íliš vysoký tlak" nebo 

"P

ř

íliš nízký tlak") je odesláno k jednomu relé.

–  Hromadná hlášení

 

N

ě

kolik hlášení z r

ů

zných zdroj

ů

 údaj

ů

 (kombino-

vaných základním sb

ě

ra

č

em dat a nouzovým signálem 

Dräger) je odesláno k jednomu relé.

– Poruchy komunikace

 

Reléový modul se v pravidelných intervalech dotazuje 
datových zdroj

ů

 adresovaných na tento modul na jejich 

okamžité vstupní stavy. Pokud od n

ě

kterého zdroje 

opakovan

ě

 nedostane odpov

ěď

, m

ů

že být tento stav – 

za p

ř

edpokladu p

ř

íslušného nastavení – sd

ě

len 

prost

ř

ednictvím reléového signálu (relé poruchy). 

V takovém p

ř

ípad

ě

 je použito relé 

č

. 8.

Summary of Contents for G 50770

Page 1: ...00137296 Installation Instructions Instructions for Use Mont n n vod N vod k pou it Gas Management Monitor R...

Page 2: ...ystem 10 Maintenance intervals 10 Technical data 11 Acceptance and handover to the operator 12 System overview 13 Obsah Pro va i bezpe nost 3 P edpokl dan pou it 4 Mont 4 Mont Monitoru R 4 P prava p i...

Page 3: ...endations given above The warranty and liability provisions of the terms of sale and delivery of Dr gerwerk Aktiengesellschaft are likewise not modified by the recommendations given above Dr gerwerk A...

Page 4: ...L x H 160 x 360 x 100 mm Monitor R dimensions W x L x H 86 x 105 x 58 mm 00137296 00237296 105 58 86 19 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36...

Page 5: ...cable types should be agreed with the design department for each project LON Local Operating Network regi stered trade mark of the Echelon com pany P prava p ipojovac ho kabelu Provozn nap t Voliteln...

Page 6: ...hen using 24V DC Ensure correct polarity 00337296 Ub Ub Schirm1 Shield 1 La1 Lb1 00437296 IN OUT 1 2 3 4 LA LB S LA LB S LA LB S LA LB S LA LB S F1 F 6 3 A 24V Network 24V Network Syst mov kabel s t G...

Page 7: ...al 23 Ground to connection 24 NC NC 1 Test Service Digitaleingang 2 3 4 5 6 7 8 13 23 33 43 34 44 14 24 Relais 53 63 73 83 74 84 54 64 Relais Bus SH Bus B Bus A OUT IN 24V 24V NC neobsazeno P pojky Vs...

Page 8: ...ease note that for fault free operation in the network a terminating resistor LON terminator G 50 769 or Monitor CC G 50 718 is required Ulo te kabel v krabici tak aby se elektronick sou sti a st n n...

Page 9: ...s status with the appropriate configuration can be transmitted via a relay signal fault relay In this case relay No 8 is used Provoz kolem rel ov ho modulu je odes lat jednotliv a hromadn hl en s t ze...

Page 10: ...ck and visual inspection by specially trained experts We recommend that you take out a Service Contract with Dr ger Service 00637296 19 1 2 3 5 6 7 8 9 10 11 12 13 14 15 16 17 18 20 21 22 24 25 26 27...

Page 11: ...ing current DC1 24V 150 mA Max switching current DC13 24V 50 mA Code UMDNS Universal Medical Device Nomenclature System 18 046 Technick daje Po adavky na okoln prost ed Teplota 15 o C a 40 o C Relativ...

Page 12: ...st be recorded in writing Following acceptance the operational system complete with associated documents is handed over to the operator Handover must be recorded in an official document Schv len a p e...

Page 13: ...W UP Set 310 G 50 742 HW UP Set 400 G 50 743 AP Set 250 G 50 745 AP Set 310 G 50 746 AP Set 400 G 50 747 AP Housing 360 G 50 748 P ehled syst mu Pro datovou s t syst mu zen plyn se dod vaj tyto sou st...

Page 14: ...rail G 50 731 Communication cable e g GM network system cable G 50 750 Designation description Part No Sou sti syst mu jsou mezi sebou propojeny s t LON V jednom segmentu sm b t vz jemn propojeno max...

Page 15: ...15 This page intentionally left blank T to strana bola ponechan z merne pr zdn...

Page 16: ...beck 49 451 8 82 0 FAX 49 451 8 82 20 80 http www draeger com 90 55 461 MA GA 6918 020 en cs Dr gerwerk AG Co KGaA Edition 1 2015 10 Subject to alteration 90 55 461 MA GA 6918 020 en cs Dr gerwerk AG...

Reviews: