Dräger G 50770 Installation Instructions & Instructions For Use Download Page 13

13

System overview

P

ř

ehled systému

System overview

The following components are available for the 
Gas Management data network:

Designation/description

Part No.

Monitor CC

G 50 718

Monitor G, comprising

Monitor base

G 50 720

Front panel set 1/Monitor G

G 50 701

Front panel set 2/Monitor G

G 50 702

Front panel set 3/Monitor G

G 50 703

Monitor 3G

G 50 726

Monitor 3G/Network

G 50 706

Monitor 6G

G 50 727

Monitor 6G/Network

G 50 707

Monitor L/Network

G 50 712

Monitor LL/Network

G 50 711

Monitor LLT/Network

G 50 710

Data collector base/Network

G 50 716

Data collector expansion 16 D

G 50 732

Monitor R

G 50 770

LON

®

 Terminator

G 50 769

Accessories

Power Supply 30 W AC

G 50 790

Power Supply 75 W AC

G 50 791

Power Supply 150 W AC

G 50 792

HW/UP Set 250

G 50 741

HW/UP Set 310

G 50 742

HW/UP Set 400

G 50 743

AP Set 250

G 50 745

AP Set 310

G 50 746

AP Set 400

G 50 747

AP Housing 360

G 50 748

P

ř

ehled systému

Pro datovou sít’ systému 

ř

ízení plyn

ů

 se dodávají tyto 

sou

č

ásti:

Název/popis

Č

. dílu

Monitor CC

G 50718

Monitor G, sou

č

ásti:

Základna

G 50720

Sada 

č

elního panelu 1 / Monitor G

G 50701

Sada 

č

elního panelu 2 / Monitor G

G 50702

Sada 

č

elního panelu 3 / Monitor G

G 50703

Monitor 3G

G 50726

Monitor 3G / sít’

G 50706

Monitor 6G

G 50727

Monitor 6G / sít’

G 50707

Monitor L / sít’

G 50712

Monitor LL / sít’

G 50711

Monitor LLT / sít’

G 50710

Základní sb

ě

ra

č

 dat / sít’

G 50716

Rozší

ř

ení sb

ě

ra

č

e dat 16 D

G 50732

Monitor R

G 50770

Zakon

č

ovací odpor LON

®

G 50769

P

ř

íslušenství

Napájecí zdroj 30 W AC

G 50790

Napájecí zdroj 75 W AC

G 50791

Napájecí zdroj 150 W AC

G 50792

HW sada pod omítku 250

G 50741

HW sada pod omítku 310

G 50742

HW sada pod omítku 400

G 50743

Sada na omítku 250

G 50745

Sada na omítku 310

G 50746

Sada na omítku 400

G 50747

Krabice na omítku 360

G 50748

Summary of Contents for G 50770

Page 1: ...00137296 Installation Instructions Instructions for Use Mont n n vod N vod k pou it Gas Management Monitor R...

Page 2: ...ystem 10 Maintenance intervals 10 Technical data 11 Acceptance and handover to the operator 12 System overview 13 Obsah Pro va i bezpe nost 3 P edpokl dan pou it 4 Mont 4 Mont Monitoru R 4 P prava p i...

Page 3: ...endations given above The warranty and liability provisions of the terms of sale and delivery of Dr gerwerk Aktiengesellschaft are likewise not modified by the recommendations given above Dr gerwerk A...

Page 4: ...L x H 160 x 360 x 100 mm Monitor R dimensions W x L x H 86 x 105 x 58 mm 00137296 00237296 105 58 86 19 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36...

Page 5: ...cable types should be agreed with the design department for each project LON Local Operating Network regi stered trade mark of the Echelon com pany P prava p ipojovac ho kabelu Provozn nap t Voliteln...

Page 6: ...hen using 24V DC Ensure correct polarity 00337296 Ub Ub Schirm1 Shield 1 La1 Lb1 00437296 IN OUT 1 2 3 4 LA LB S LA LB S LA LB S LA LB S LA LB S F1 F 6 3 A 24V Network 24V Network Syst mov kabel s t G...

Page 7: ...al 23 Ground to connection 24 NC NC 1 Test Service Digitaleingang 2 3 4 5 6 7 8 13 23 33 43 34 44 14 24 Relais 53 63 73 83 74 84 54 64 Relais Bus SH Bus B Bus A OUT IN 24V 24V NC neobsazeno P pojky Vs...

Page 8: ...ease note that for fault free operation in the network a terminating resistor LON terminator G 50 769 or Monitor CC G 50 718 is required Ulo te kabel v krabici tak aby se elektronick sou sti a st n n...

Page 9: ...s status with the appropriate configuration can be transmitted via a relay signal fault relay In this case relay No 8 is used Provoz kolem rel ov ho modulu je odes lat jednotliv a hromadn hl en s t ze...

Page 10: ...ck and visual inspection by specially trained experts We recommend that you take out a Service Contract with Dr ger Service 00637296 19 1 2 3 5 6 7 8 9 10 11 12 13 14 15 16 17 18 20 21 22 24 25 26 27...

Page 11: ...ing current DC1 24V 150 mA Max switching current DC13 24V 50 mA Code UMDNS Universal Medical Device Nomenclature System 18 046 Technick daje Po adavky na okoln prost ed Teplota 15 o C a 40 o C Relativ...

Page 12: ...st be recorded in writing Following acceptance the operational system complete with associated documents is handed over to the operator Handover must be recorded in an official document Schv len a p e...

Page 13: ...W UP Set 310 G 50 742 HW UP Set 400 G 50 743 AP Set 250 G 50 745 AP Set 310 G 50 746 AP Set 400 G 50 747 AP Housing 360 G 50 748 P ehled syst mu Pro datovou s t syst mu zen plyn se dod vaj tyto sou st...

Page 14: ...rail G 50 731 Communication cable e g GM network system cable G 50 750 Designation description Part No Sou sti syst mu jsou mezi sebou propojeny s t LON V jednom segmentu sm b t vz jemn propojeno max...

Page 15: ...15 This page intentionally left blank T to strana bola ponechan z merne pr zdn...

Page 16: ...beck 49 451 8 82 0 FAX 49 451 8 82 20 80 http www draeger com 90 55 461 MA GA 6918 020 en cs Dr gerwerk AG Co KGaA Edition 1 2015 10 Subject to alteration 90 55 461 MA GA 6918 020 en cs Dr gerwerk AG...

Reviews: