background image

ABIL-R

Series of compressed air line breathing 
apparatus
Instructions for use

For your safety

Strictly follow the Instructions for use.

 Any use of the apparatus requires full 

understanding and strict observation of these instructions. The apparatus is only 
to be used for purposes specified here.

Maintenance:

 Only authentic Dräger spare parts may be used for maintenance. 

We recommend that you take out a service contract with Dräger Service.

Liability for proper function or damage: 

The liability for the proper function of 

the apparatus is irrevocably transferred to the owner or operator to the extent 
that the apparatus is serviced or repaired by personnel not employed or 
authorized by DrägerService or if the apparatus is used in a manner not 
conforming to its intended use. Dräger cannot be held responsible for damage 
caused by non-compliance with the recommendations given above. The 
warranty and liability provisions of the terms of sale and delivery of Dräger are 
likewise not modified by the recommendations given above.
Dräger Safety AG & Co. KGaA

Intended use

These instructions for use apply for the following basic equipment versions:

Configurations of the ABIL-R with half masks meet the requirements of 
specific device class 2B.
Configurations of the ABIL-R with full face masks meet the requirements of 
specific device class 4B.

The compressed air line breathing apparatus of series ABIL-R is designed for 
use in the trades, industry and agriculture. It protects the respiratory organs 
against the effects of harmful substances.
The apparatus is tested to EN 14594:2005.
It is marked "F" and suitable for use in inflammable atmospheres

The compressed air line breathing apparatus ABIL-R comprises

1–2

Full-face mask, breathing hose 

5

Basic apparatus

6–11

Compressed air supply

Various facepieces from the Dräger range can be used for the mask, 
see "Order list".

The basic apparatus comprises

3

Belt unit (waist belt with manifold) 

4

Hose 

5

Manifold, if applicable

6–11

Compressed air supply

Depending on the purpose for which the apparatus is used, the belt unit 
may be as follows:

From a compressed air mains through compressed air fine filters or 
the filter station 

(4, 5, 6, 7, 10)

B

From a compressed air cylinder via pressure reducer 

(4, 5, 8, 9)

,

C

From a mobile compressed air source, e.g. Airpack, Quad Pack 

(4, 5, 11)

Depending on the purpose for which the apparatus is used, the belt unit may be 
used as follows:

ABIL-R-1

Features an inlet for the compressed air supply hose (maximum length 50 m and 
with a maximum of 2 hoses) and an outlet for connecting the breathing hose (and 
full-face mask).
The air flow can be adjusted to the demand via an integrated control valve. The 
control valve cannot be closed completely and 

must not be used as shutoff 

valve.

ABIL-R-2

As ABIL-R-1, but with additional port for connecting equipment, e.g. paint spray 

gun. This port must not be used

to connect a second demand valve or
to connect the Y-piece R 27 945.

The manifold can be worn on either the right or left-hand side of the waist.
Turn the clip when changing over.

Use

Alternative A (supply from a stationary breathing air network (loop)):

3

Put on belt unit. Adjust length if necessary.

4

Connect compressed air supply hose (maximum length 50 m) to 
manifold:
Press coupling halves together until they engage.

Note for your own safety:
Check that the connection is tight by pulling on the air line.
Before every use, check that the hose connection to the housing 
is screwed tight (do not use tools).

10

Connect compressed air fine filter or filter station to compressed air 
supply hose.

5

If necessary, insert Y-piece for supplying a second user of the 
apparatus.

7

Connect the compressed air line (maximum length 3 m) to the 
compressed air fine filter or the filter station and stationary breathing 
air network.

Start up compressed air supply system (8 bar).

2

Connect breathing hose to manifold.

1

Put on full-face mask

1)

 and connect to breathing hose.

3

Set required air flow on control valve.

The compressed air line breathing apparatus is ready for use.

Alternative B (compressed air supplied from a cylinder):

As alternative A, but

9

Connect pressure reducer to 
compressed air cylinder. 
Must be connected by hand, do not use 
tools.
Connect compressed air supply hose to 
pressure reducer.

8

Open valve on compressed air cylinder 
and read off value on pressure gauge.

Always use a full compressed air cylinder.

The pressure reducer should be set to 8 bar. Proceed as follows if 
adjustment is necessary:

Connect compressed air line breathing apparatus to the plug-in 
coupling.

Undo lock nut, set value with adjusting screw then retighten lock nut.

Description

See illustration on page 3

NOTICE

Before use, ensure that the air source can supply the planned 
number of users with breathing air (see IfUs of the supply units).

WARNING

In certain highly toxic atmospheres, the respiratory protective 
device does not provide adequate protection.
The respiratory protective device does not protect against 
radioactive radiation.
If the work is very intense, the pressure in the facepiece may 
become negative due to the maximum inhalation air flow.
If ABIL-R is used with a mobile compressed air supply unit, a 
helper has to be there to inform the user and tell him to stop 
working if the remaining pressure warning of the supply unit is 
activated.
The operator has to ensure that accidental coupling of the ABIL-
R air supply system to other pipe systems that contain other 
gases than breathing air is not possible.

1)

Note the associated instructions for use.

Only use respiratory air conforming to EN 12 021.
The apparatus can only be used without risk at temperatures < 0 °C 
if steps are taken to ensure that the compressed air being used also 
conforms to EN 12 021 with regard to the moisture content 
(< 50 mL/m

3

 depressurized air).

i

i

!

Summary of Contents for ABIL-R Series

Page 1: ...Notice d utilisation 10 nl Gebruiksaanwijzing 13 es Instrucciones de uso 16 it Istruzioni per l uso 19 ptBR Instru es de servi o 22 da Brugsanvisning 25 no Bruksanvisning 28 sv Bruksanvisning 31 fi K...

Page 2: ...2 Bitte aufklappen Please fold out D pliez s v p Openklappen a u b Abrir aqu Si prega di ribaltare Fold venligst ud Favor de abrir Brett opp V g ppna K nn sivua L tfen a n z...

Page 3: ...Configuratiemogelijkheden Posibilidades de configuraci n Opzioni di configurazione Possibilidades de configura o Konfigurationsmuligheder Konfigurasjonsmuligheter Konfigurationsm jligheter Konfiguroin...

Page 4: ...wie ABIL R 1 jedoch mit zus tzlichem Ausgang f r den Anschluss eines Arbeitsger tes z B Farbspritz Pistole Dieser Ausgang darf nicht benutzt werden f r den Anschluss eines zweiten Lungenautomaten ode...

Page 5: ...ohne Verformung trocken k hl und staubfrei lagern Vor direkter Licht und W rmeeinstrahlung sch tzen ISO 2230 und nationale Richtlinien f r Lagerung Wartung und Reinigung von Gummierzeugnissen beachten...

Page 6: ...BIL R 1 AL 01 265 ABIL R 2 AL 01 266 F r die Versorgung aus ortsfestem Atemluftnetz Ringleitung Anschluss Set 3 4 AL 01 233 Filterstation AF 1400 SR 05 104 Druckluft Feinfilter R 27 944 Druckluft Fein...

Page 7: ...itional port for connecting equipment e g paint spray gun This port must not be used to connect a second demand valve or to connect the Y piece R 27 945 The manifold can be worn on either the right or...

Page 8: ...ed Keep away from direct light and heat Observe ISO 2230 and national regulations for the storage maintenance and cleaning of rubber products Technical data Troubleshooting Maintenance intervals 1 Not...

Page 9: ...01 265 ABIL R 2 AL 01 266 For supply from a stationary breathing air network loop Connection set 3 4 AL 01 233 Filter station AF 1400 SR 05 104 Fine compressed air filter R 27 944 Fine compressed air...

Page 10: ...peut pas tre ferm e compl tement ABIL R 2 idem ABIL R 1 mais avec une sortie suppl mentaire pour le raccordement d un outil p ex pistolet air comprim Cette sortie ne doit pas tre utilis e pour le rac...

Page 11: ...t propre Garder l abri du soleil et des rayons thermiques Respecter la norme ISO 2230 et les directives nationales pour le stockage la maintenance et le nettoyage de produits en caoutchouc Caract rist...

Page 12: ...l alimentation partir d un r seau d air comprim stationnaire r seau en boucle Kit de raccords 3 4 AL01233 Station de filtrage AF 1400 SR 05 104 Filtre fin pour air comprim R 27 944 Cartouche du filtre...

Page 13: ...er met aanvullende uitgang voor het aansluiten van gereedschap bijv een verfspuit Deze uitgang mag niet worden gebruikt voor het aansluiten van een ademautomaat of voor het aansluiten van het Y stuk R...

Page 14: ...n zonder vervorming droog koel en stofvrij opslaan ISO 2230 en nationale richtlijnen voor opslag onderhoud en reiniging van rubberproducten in acht nemen Technische gegevens Hulp bij pech Intervallen...

Page 15: ...IL R 1 AL 01 265 ABIL R 2 AL 01 266 Voor de voeding uit een stationair ademhalingsluchtnet ringleiding Aansluitset 3 4 AL01233 Filterstation AF 1400 SR 05 104 Perslucht microfilter R 27 944 Perslucht...

Page 16: ...v lvula reguladora integrada la cantidad de aire puede adaptarse al esfuerzo La v lvula reguladora no sirve como v lvula de cierre no se puede cerrar por completo ABIL R 2 como ABIL R 1 pero con sali...

Page 17: ...m scara facial completa Cerrar la v lvula reguladora y bloquear la v lvula de exceso Se tiene que percibir un flujo volum trico de aire reducido Abrir la v lvula reguladora completamente Se tiene que...

Page 18: ...esde una red fija de aire de respiraci n conducto circular Juego de conexi n 3 4 AL01233 Estaci n de filtrado AF 1400 SR 05 104 Filtro fino para aire comprimido R 27 944 Cartucho para filtro fino para...

Page 19: ...aria pu essere adattata al carico tramite una valvola di regolazione integrata La valvola di regolazione non serve come valvola d intercettazione essa non pu essere chiusa completamente ABIL R 2 Come...

Page 20: ...o facciale Chiudere la valvola regolatrice e assicurare la tenuta della valvola di supero Si dovrebbe avvertire una minore portata in volume dell aria Aprire completamente la valvola regolatrice Si do...

Page 21: ...2 AL 01 266 Per l alimentazione da una rete fissa locale di aria respirata tubazione ad anello Set di collegamento 3 4 AL01233 Stazione filtrante AF 1400 SR 05 104 Filtro fine aria compressa R 27 944...

Page 22: ...a v lvula de regula o integrada A v lvula de regula o n o serve como v lvula de bloqueio n o pode ser fechada completamente ABIL R 2 como o ABIL R 1 mas com sa da adicional para a conex o de um aparel...

Page 23: ...excesso Tem de ser percet vel um ligeiro caudal de ar Abrir completamente a v lvula reguladora Tem de ser percet vel um grande caudal de ar Armazenagem Armazenar todas as pe as sem deforma o num s tio...

Page 24: ...01 266 Para o abastecimento da rede fixa de ar respirat rio linha anular Conjunto de conex o 3 4 AL01233 Esta o de filtragem AF 1400 SR 05 104 Filtro fino de ar comprimido R 27 944 Cartucho do filtro...

Page 25: ...a udgang til tilslutning af et arbejdsapparat fx spr jtepistol Denne udgang m ikke benyttes til tilslutning af en lungeautomat eller til tilslutning af Y stykket R 27 945 Fordeleren kan b res p s vel...

Page 26: ...lys og varmep virkning F lg ISO 2230 og de nationale bestemmelser for opbevaring vedligeholdelse og reng ring af gummiprodukter Tekniske data Afhj lpning af fejl Vedligeholdelsesintervaller 1 Tilh re...

Page 27: ...teenhed ABIL R 1 AL 01 265 ABIL R 2 AL 01 266 For tilf rsel fra station rt system for ind ndingsluft ringledning Tilslutningss t 3 4 AL01233 Filterstation AF 1400 SR 05 104 Trykluftfinfilter R 27 944...

Page 28: ...stra uttak for tilkopling av et arbeidsapparat f eks malingsspr ytepistol Dette uttaket m ikke benyttes for tilkopling av en doseringsventil eller for tilkopling av Y stykket R 27 945 Fordeleren kan h...

Page 29: ...st vfritt Beskytt dem mot direkte lys og varmestr ling F lg ISO 2230 og nasjonale retningslinjer for lagring vedlikehold og rengj ring av gummiprodukter Tekniske data Probleml sning Vedlikeholdsinterv...

Page 30: ...et ABIL R 1 AL 01 265 ABIL R 2 AL 01 266 For tilf rsel fra stasjon rt puste luftnett ringledning Koblingssett 3 4 AL01233 Filterstasjon AF 1400 SR 05 104 Trykkluft mikrofilter R 27 944 trykkluft mikro...

Page 31: ...f rgspruta Denna utg ng f r inte anv ndas f r anslutning av en andningsventil eller f r anslutning av Y stycket R 27 945 F rdelaren kan b ras s v l till v nster som h ger p midjan Vrid clipset vid byt...

Page 32: ...direkt ljus och v rmebestr lning F lj ISO 2230 och nationella riktlinjer f r f rvaring underh ll och reng ring av gummiprodukter Tekniska data Hj lp vid funktionsst rning Underh llsintervaller 1 F lj...

Page 33: ...1 AL 01 265 ABIL R 2 AL 01 266 F r f rs rjning fr n station rt andningsluftn t ringledning Anslutningsset 3 4 AL 01 233 Filterstation AF 1400 SR 05 104 Tryckluftsfinfilter R 27 944 Tryckluftsfinfilte...

Page 34: ...ei saa k ytt toisen paineilmahengityslaitteen liitt miseksi tai Y kappaleen R 27 945 liitt miseksi Jako osaa voidaan kantaa vy t r ll joko oikealla tai vasemmalla puolella Vaihdettaessa k nn liitin K...

Page 35: ...aikassa Suojaa suoralta valolta ja l mm lt Noudata standardin SFS ISO 2230 sis lt mi kumituotteiden s ilytyst huoltoa ja puhdistusta koskevia ohjeita Tekniset tiedot Vianm ritys Huoltov lit 1 Noudata...

Page 36: ...1 265 ABIL R 1 AL 01 266 Sy tt n kiinte st hengitysilmaverkosta rengasjohto Liit nt setti 3 4 AL01233 Suodatinasema AF 1400 SR 05 104 Paineilman hienosuodatin R 27 944 Paineilman hienosuodattimen pano...

Page 37: ...ihaz n rn boya tabancas ba lanmas i in ek bir k a sahiptir Bu ikinci k asla ikinci bir akci er otomat n n ba lanmas i in veya R 27 945 Y par as n n ba lanmas i in kullan lmamal d r Da t c belin sa nda...

Page 38: ...serin ve tozsuz bir ortamda muhafaza ediniz Do rudan etki eden s cakl ktan ve g n ndan koruyunuz ISO 2230 u ve plastik r nlerin depolamas na bak m na ve temizlenmesine y nelik ulusal y netmelikleri d...

Page 39: ...66 Bulunulana mekana sabit ba l solunum havas ebekesinden besleme kapal devre hat Ba lant seti 3 4 AL 01 233 Filtre istasyonu AF 1400 SR 05 104 Bas n l hava hassas ince filtresi R 27 944 Bas n l hava...

Page 40: ...y AG Co KGaA ABIL R 2 ABIL R 4 ABIL R EN 14594 2005 F ABIL R 1 2 3 5 6 11 Dr ger 3 4 5 6 11 EN 12 021 A 4 5 6 7 10 B 4 5 8 9 C Airpack Quad Pack 4 5 11 ABIL R 1 50 m 2 ABIL R 2 ABIL R 1 R 27 945 A 3 4...

Page 41: ...A 6 5 A 7 2 A 1 A 1 1 4 3 Sekusept Cleaner2 7 10 bar ABIL R1 ABIL R2 ISO 2230 1 2 Ecolab D 40589 D sseldorf 3 m 50 m EN 12 021 7 10 bar 10 C 60 C 300 1 000 EN 12 021 6 1 1 X X X X X X X X X X X2 2 Dr...

Page 42: ...56 310 X plore 6300 EPDM PMMA RA K bl R 55 800 X plore 6530 EPDM PC CR R 1525 R 54 910 ABIL R 1 AL 01 265 ABIL R 2 AL 01 266 3 4 AL01233 AF 1400 SR 05 104 R 27 944 CH 106 R 27 945 5 m AL 01 260 10 m...

Page 43: ......

Page 44: ......

Page 45: ......

Page 46: ...6 Subject to alteration Dr ger Safety AG Co KGaA Revalstrasse 1 23560 Luebeck Tel 49 451 882 0 Fax 49 451 882 2080 www draeger com Notified body Involved in type approval and in quality control DEKRA...

Reviews: