Loosen the six
screws 3
and remove them.
•
Lift the
filter disk 4
off the six
retaining an-
gles 5
.
Always place the filter disk on a soft, non-
scratching base to preserve its surface.
•
Remove the six
retaining angles 5
.
•
Remove the
retaining ring 6
of the dispersion
lens.
•
Remove the
dispersion lens 7
.
Always place the dispersion lens on a soft,
non-scratching base to preserve its sur-
face.
•
Mount the new
dispersion lens 7
.
ATTENTION: Only use dispersion lenses,
that have been cleaned properly
(see chap-
ter 3.2)
.
•
Mount the
retaining ring 6
, the
retaining an-
gles 5
, the
filter disk 4
in reverse order and fix
the retaining angles with the six
screws 3
.
•
Mount the
optic ring 2
in reverse order (anti-
clockwise rotation).
For mounting position the
optic ring 2
, so the
toothed wheel segment 8
of the ring and the
toothed wheel 9
in the lower housing part
work into each other.
•
Fix the optic ring by turning the
screw 1
clock-
wise.
3
4
5
6
7
1
8
2
9
On request of the customer there are spare parts lists and wiring diagrams available for the lamps
Mach M5 F / Mach M5 DF.
59270001
Edition 06