WIL-12330-E-08
Wilden
®
8
PERFORMANCE
PS2 SANIFLO™ HS
RUBBER-FITTED
Ship Weight ........................ 40 kg (80 lb.)
Air Inlet................................................ 1/2"
Inlet ....................................... 25 mm (1")
Outlet ....................................... 25 mm (1")
Suction Lift ...................... 3.9 m Dry (13')
7.6 m Wet (25')
Disp. Per Stroke
1
................. 0.2 L (0.07 gal.)
Max. Flow Rate ............ 121 lpm (32 gpm)
Max. Size Solids ................... 6.4 mm (1/4")
1
Displacement per stroke was calculated
at 4.8 bar (70 psig) air inlet pressure
against a 2.1 bar (30 psig) head pressure.
Example:
To pump 87 lpm (23 gpm)
against a discharge head of 2.8 bar
(40 psig) requires 6.9 bar (100 psig)
and 68 Nm
3
/h (40 scfm) air consumption.
Caution: Do not exceed 8.6 bar (125 psig)
air supply pressure.
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily
operation parameters will fall in the center of the pump's performance curve.
PS2 SANIFLO™ HS
FULL-STROKE TPE
INTEGRAL PISTON
DIAPHRAGM-FITTED
Ship Weight .......................... 40 kg (80 lb.)
Air Inlet.................................................. 1/2"
Inlet ......................................... 25 mm (1")
Outlet ......................................... 25 mm (1")
Suction Lift .......................... 2.4 m Dry (8')
7.9 m Wet (26')
Disp. Per Stroke
1
.................... 0.2 L (0.07 gal.)
Max. Flow Rate .............. 117 lpm (31 gpm)
Max. Size Solids ..................... 6.4 mm (1/4")
1
Displacement per stroke was calculated
at 4.8 bar (70 psig) air inlet pressure
against a 2.1 bar (30 psig) head pressure.
Example:
To pump 41 lpm (11 gpm)
against a discharge head of 2.8 bar
(40 psig) requires 4.1 bar (60 psig)
and 35 Nm
3
/h (21 scfm) air consumption.
Caution: Do not exceed 8.6 bar (125 psig)
air supply pressure.
Section 5
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily
operation parameters will fall in the center of the pump's performance curve.