WIL-12330-E-08
Wilden
®
16
Disassembly / Reassembly
Step 10A
Next, remove the liquid chamber from the
center section assembly.
Step 10B
If your pump is fitted with an integral piston
diaphragm (IPD), when you remove the
liquid chamber you will notice that there is
no outer piston.
Step 11A
Using two (2) adjustable wrenches, turning
in the opposite direction, loosen and
remove one of the two outer pistons.
Step 11B
If your pump is fitted with an IPD, the
procedure for removing the diaphragm is
slightly different. In this case, simply grasp
the diaphragm in two locations and turn in a
counterclockwise direction.
Step 12A
After loosening and removing the outer
piston, the remaining diaphragm assembly
and shaft can be removed from the center
section assembly..
Step 12B
If your pump is fitted with an IPD, the
procedure for removing the diaphragm is
the same.