Disassembly / Reassembly
Step 4
Next, remove the clamp bands
that secure the ball valve
housing to the liquid chamber.
Step 5
Next, remove the ball valve
housing, valve ball and gasket.
Step 6
Loosen the wing nut and remove the
inlet manifold clamp bands.
Step 7
Next, remove the clamp bands that
secure the ball valve housing to the
liquid chamber.
Step 8
Next, remove the ball valve
housing, valve ball and gasket
from liquid chamber. To ensure
proper alignment during
reassembly of manifold/liquid
chamber interface, turn off-set
portion of valve housing to the left
or to the right. This procedure
works for the inlet manifold and
discharge manifold connections.
Step 9
Now the large clamp bands can be
removed.
NOTE:
Prior to assembly,
alignment marks should be
placed on the liquid chambers
and air chambers to assist
with proper alignment during
reassembly.