WIL-12330-E-08
Wilden
®
18
Swivel Pump Stand Option
For ease of maintenance and cleaning, Wilden offers an optional swivel pump stand. The swivel pump stand allows the
pump to be drained by rotating the pump so that the fluid can flow out of the discharge and into a suitable container
Draining Pump Contents
To drain the pump of its contents, first disconnect the inlet and discharge
connections. Next loosen the anti-rotation bolt (item #1) by turning counter-
clockwise. Do not remove the bolt; only loosen the bolt two turns. After
loosening the anti- rotation bolt, rotate pump 180°. This will allow the
contents within the pump to flow out of the discharge and into a suitable
container. After draining the pump, rotate the pump
back to the upright position and tighten the anti-rotation bolt.
Removing Pump From Swivel Pump Stand
Saniflo™ HS pumps are very heavy. It is recommended that the pump be
disassembled while attached to the stand. If it is necessary to remove the
pump from the stand while fully assembled, use a hoist or mechanical
means to support the pump as it is removed from the stand.
To remove your Saniflo™ HS pump from the swivel pump stand, first
loosen the anti-rotation bolt (item #1) by turning counter-clockwise. Next,
ensure the entire pump weight is supported by hoist and loosen the locking
pin (item #2) by turning counter-clockwise. This will allow the pump to be
removed from the stand.
CAUTION:
Removal of the locking pin (item #2) will allow the
pump to fall from the stand, potentially causing injury to the
operator or personnel in the immediate area. Never operate or
store the pump without the locking pin (item #2) in place and
properly torqued.
NOTE:
The center
block-to-bushing bolts
(item #4) attach the
center block
mounting bushing
(item #3) to the center
block (not shown).
These bolts do not
need to be removed
to remove the pump
from the stand.
NOTE:
Torque values
are located in Section
7 of this manual.
Swivel Pump Stand