Excessive line drop for Wire Gauge and
Distance
Above
includes
9
amps
@
12
vdc
for
D2
Cool
Dome
typical
current
draw,
with
3
amps
for
max.
camera
&
accessory
draw.
Voltage
Drop
Equation
to
Determine
Minimum
Wire
Gauge
to
be
Used
on
D/C
run
Between
the
S
‐
250
‐
12
Power
Supply
to
D2
Cool
Dome.
Vd
=
voltage
drop
for
12vdc
run
(nominal)
D
=
distance
of
run
(ft)
Vgm
=
gauge
multiplier
(vdc
drop,
per
foot)
Vd
=
D
x
Vgm
Where
we
conservatively
try
to
keep
the
voltage
drop
under
1.2
vdc
over
the
low
voltage
direct
current
run.
These
multipliers
are
approximate,
and
voltage
drop
(Vd)
is
maximum
at
full
12
amp
load
at
12
vdc.
This
voltage
drop
is
under
fully
loaded
condition,
when
the
cooling
unit
is
engaged,
and
camera
and
all
accessories
are
on.
Voltage
drop
will
be
much
less,
if
the
current
is
not
at
full
load.
Reusable
Desiccant
Canister
The
reusable
desiccant
canister
contains
forty
grams
of
silica
gel.
This
will
prevent
moisture
buildup
inside
the
Cool
Dome.
Make
sure
to
remove
the
canister,
located
below
the
camera
mount,
from
its
packaging
before
the
Cool
Dome
is
put
to
use.
There
is
a
small
window
on
the
canister
(white
circle).
Ensure
that
the
crystals
are
blue.
Occasionally,
especially
in
humid
environments,
the
canister
may
need
to
be
serviced.
If
so,
the
crystals
in
the
window
turn
pink,
and
the
silica
gel
is
saturated
with
moisture
and
can
be
reactivated
by
being
placed
in
an
oven
at
300
°F
for
three
hours
or
until
the
crystals
turn
blue
again.
The
gel
can
be
reactivated
virtually
an
infinite
number
of
times.
Humidity
control/
Dessicant
cannister
should
be
removed
from
its
foil
packaging
and
secured
within
enclosure
out
of
the
way.
The
clear
window
shown
in
the
white
circle
should
be
blue
when
completely
dry.
28