82
LED descriptions
NOTE:
for information on power-cycling enclosures.
4144 drive enclosure rear panel LEDs
The rear panel layout of the 4144 drive enclosure is shown below. Using mini-SAS (SFF-8088) external
connectors, this drive enclosure supports a 6-Gbps data rate for backend SAS expansion. See
for more information.
Figure 45
LEDs: 4144 drive enclosure — rear panel
LED No./Description
Color
State
Definition
1 — Power Supply
—
—
See
2 — Unit Locator
White
Off
Blink
Normal operation.
Physically identifies the expansion module.
3 — OK to Remove
Blue
Off
Not implemented.
4 — Fault/Service Required
Amber
On
Blink
A fault is detected or a service action is required.
Hardware-controlled power-up.
5 — FRU OK
Green
On
Off
Blink
Expansion module is operating normally.
Expansion module is not OK.
System is booting.
6 — SAS In Port Status
Green
On
Off
Port is connected and the link is up.
Port is empty or link is down.
7 — SAS Out Port Status
Green
On
Off
Port is connected and the link is up.
Port is empty or link is down.
IN
OUT
IN
OUT
6Gb/s
6Gb/s
6Gb/s
6Gb/s
1
2
6
3
5
4
7
1