AssuredSAN Ultra48 Series Setup Guide
41
•
Be sure of the desired link type before creating the replication set, because you cannot change the
replication link type after creating the replication set.
•
For the sake of system security, do not unnecessarily expose the controller module network port to an
external network connection.
Conceptual cabling examples are provided addressing cabling on the same network and cabling relative
to physically-split networks.
IMPORTANT:
AssuredRemote must be licensed on all systems configured for replication, and the controller
module firmware must be compatible on all systems licensed for replication.
NOTE:
Systems must be correctly cabled before performing replication. See the following documents for
more information about using AssuredRemote to perform replication tasks.
•
AssuredSAN 4004 Series RAIDar User Guide
•
AssuredSAN 4004 Series CLI Reference Guide
Cabling for replication
This section shows example replication configurations for CNC-based 4844 controller enclosures. The
following illustrations provide conceptual examples of cabling to support AssuredRemote replication. Blue
cables show I/O traffic and green cables show replication traffic.
NOTE:
A simplified version of the controller enclosure rear panel is used in cabling illustrations to portray
either FC or iSCSI host interface protocol. The rear panel layouts for the three CNC models are identical;
only the external connectors used in the host interface ports differ.
Once the 4844 systems are physically cabled, see the
AssuredSAN 4004 Series RAIDar User Guide
or
online help for information about configuring, provisioning, and using the optional AssuredRemote feature.
NOTE:
The RAIDar Replication Setup Wizard guides you through replication setup.
CNC ports and replication
CNC controller modules can use qualified SFP options of the same type, or they can use a combination of
qualified SFP options supporting different interface protocols. If you use a combination of different
protocols, then CNC ports 0 and 1 must be set to FC (either both16 Gbit/s or both 8 Gbit/s), and CNC
ports 2 and 3 must be set to iSCSI (either both 10GbE or both 1 Gbit/s). Each CNC port can perform I/O
or replication. In combination environments one interface—for example FC—might be used for I/O, and
the other interface type—10GbE or 1 Gb iSCSI—might be used for replication.
Summary of Contents for AssuredSAN 4544
Page 8: ...8 Figures ...
Page 10: ...10 Tables ...
Page 14: ...14 About this guide ...
Page 50: ...50 Connecting hosts ...
Page 52: ...52 Basic operation ...
Page 70: ...70 Troubleshooting ...
Page 90: ...90 Electrostatic discharge ...
Page 94: ...94 USB device connection ...
Page 96: ...96 SFP option for CNC ports ...
Page 100: ...100 Index ...