Troubleshooting
SYMPTOM
CAUSE
SOLUTION
Motor piston
Your
Dosatron
does not
start, or
it stops
working.
Motor piston has seized.
Restart the motor piston by
hand.
Excess flow.
1. Reduce the flow rate;
restart.
2. Check that the motor
valve seals are fitted.
Motor piston is broken.
Return the Dosatron to your
distributor.
Dosing
Water flowing
back into the
product tank.
Suction valve or valve seal
dirty, worn or missing.
Clean or replace.
No suction of
product.
The motor piston has
stopped working.
See
Troubleshooting -
Motor piston.
Air tightness problem in the
suction hose.
Check the suction hose and
the tightness of hose clamps.
Suction hose blocked or
strainer clogged.
Clean or replace them.
Suction valve seal worn,
wrongly fitted or dirty.
Clean or replace it.
Plunger seal wrongly fitted,
dirty or swollen.
Clean or replace it.
Dosing pump body
scratched.
Replace it.