INSTALLATION ADVICE
The Dosatron should be installed in a full hydraulic bypass.
An in-line installation is possible but not recommended because it does not
enable the dosing pump to be easily isolated for maintenance (the water
supply must be turned off).
A by-pass installation enables the system to be supplied with clean mains
water when the Dosatron is not operating and enables it to be easily
dismantled.
If your flow rate is above the specified limits for the Dosatron, see
§ EXCESS FLOW.
To prolong the Dosatron’s service life, it should be fitted with an upstream
filter (e.g. 200 to 120 mesh - 80 to 130 microns, depending on the quality of
your water).
This precaution is essential if the water contains impurities or particles,
especially if the water comes from a well or if it is surface water.
Fig. 9
EXCESS FLOW (for information)
If your Dosatron clicks more than
44 times in 15 seconds
, (i.e. 22 cycles)
you are beyond the upper flow-capacity limit.