II
- Device group II: all areas except mining
2G
- Device category 2 for gaseous ex-atmos-
phere
Ex h - Ignition protection category for non-elec-
trical devices
IIA
- Explosion group
T4
- Temperature class
Gb
- Device protection level: Zone 1
X
- Restriction: The device is configured for
operation in an ambient temperature of
15°C to 40°C.
2.3
Residual risks
Explosion danger
Pumps with conductive Acetal parts in contact with
media may not be used with acids and lyes. Reac-
tion and explosion of these materials can cause
serious injury or death. Reaction and explosion of
these materials can cause serious injury or death.
Pump motor section
Fluid caps
Distributor
Parts in contact with material
Sparks due to electrostatic discharge
If the pump is not properly grounded or the poten-
tial equalization fails, components may get
charged electrostatically. Electrostatic discharge
can cause sparks that in explosive atmosphere
can cause a fire or an explosion. Serious injury
and death could be the consequence.
Ground Pump as specified.
Check connection of grounding cable during
operation.
Measure volume resistivity.
Media
Material escaping under pressure can cause
serious injuries.
Before working on the product:
Disconnect the system, in which the product is
installed, from compressed air and material
supply.
Depressurize the lines.
Secure the system against being switched on
again.
Observe approved operating pressures
2.4
Conduct in the event of a hazardous
situation
Conduct in case of danger depends on the opera-
tor’s installation situation.
Perform the following activities:
Close lines.
Secure against reconnection.
Depressurize lines.
2.5
Staff qualification
WARNING!
Inadequate qualification
Wrong estimation of dangers can cause serious
injury or death.
– Only sufficiently qualified persons may exe-
cute all work.
– Some work requires additional qualification.
Additional qualifications of specialized per-
sonnel are marked with a “+”.
This document is intended for qualified personnel
in industry and craftmanship.
Cleaning staff
The cleaning staff receives regular instructions
from the operator about the following contents:
Using the product
Handling cleaning tools
Handling cleaning agents
Technical Measures for occupational safety and
health
Electrician
Electricians assemble, install, service and repair
electrical systems in a professional manner.
Furthermore, electrical engineers have the fol-
lowing knowledge:
Guidelines, Standards and Rules of Engi-
neering
Local conditions
Electrical Systems and Their Loading Limits
Technical Measures for occupational safety and
health
Mechanic
The mechanic is trained specifically for the field of
work in which he works.
Furthermore, he has the following knowledge:
Guidelines, Standards and Rules of Engi-
neering
Local conditions
Technical Measures for occupational safety and
health
Safety
01/2020
EcoPump AD - MPU00013EN