11.2
Disposal
ENVIRONMENT!
Improper waste disposal
Improper waste disposal threatens the environ-
ment and prevents re-use and recycling.
– Clean components before their disposal.
– Always dispose of components in accordance
with their characteristics.
– Collect leaked out utilities and auxiliaries
completely.
– Dispose of work equipment soaked in coating
materials or operating substances according
to the disposal provisions in force.
– Dispose of utilities and auxiliaries according
to the disposal provisions in force.
– In case of doubt, refer to the local disposal
authorities.
Requirements:
Pump has been cleaned
purged
Personnel:
Mechanic
+ additional qualification explosion protection
Protective equipment:
Protective gloves
Eye protection
Anti-Static Safety Boots
1. Dispose of material residue from pump profes-
sionally.
2. Remove the seals. Ensure professional dis-
posal.
3. Dispose of individual parts of the pump profes-
sionally.
12
Technical data
12.1
Dimensions and weight
Fig. 24: Dimensions
Detail
Value
Height
498 mm
Width
334 mm
Depth
376 mm
Particle size max.
6.4mm
Weight
38.3 kg
12.2
Connections
Detail
Value
Compressed air connection
1/2" NPT (IG)
Inlet connection
1 1/2" BSP
(IG)
Outlet connection
1 1/2" BSP
(IG)
12.3
Operating conditions
Detail
Value
Operating temperature, min.
10°C
Operating temperature, max.
50°C
12.4
Operating values
Detail
Value
Control air pressure, max.
8.3 bar
Material output pressure, max.
Technical data
01/2020
EcoPump AD - MPU00013EN