11
Disassembly and Disposal
11.1
Disassembly
Turn off compressed air supply
Fig. 21: Compressed air connection
Personnel:
Mechanic
Protective equipment:
Eye protection
Protective gloves
Anti-Static Safety Boots
Protective workwear
1. Disconnect compressed air supply to the pump.
Secure against reconnection.
2. Remove compressed air connection (1) from
pump.
Switching off material supply
WARNING!
Risk of injury due to escaping material and
compressed air
Escaping compressed material can cause
serious injury.
Before carrying out any work:
– Disconnect the system, in which the pump is
installed, from compressed air and material
supply.
– Secure the system against being switched on
again.
– Depressurize the lines.
Disassembly and Disposal
01/2020
EcoPump AD - MPU00013EN