9.3.2 Dismantle inlet and outlet manifold
Removing the outlet manifold
Fig. 11: Central body with outlet manifold
Personnel:
Mechanic
Protective equipment:
Eye protection
Protective gloves
Anti-Static Safety Boots
Requirements:
Pump is properly disassembled.
1. Remove 4 screws (4) from outlet manifold (5).
2. Remove outlet manifold (5).
3. Remove 2 balls (3), 2 O-rings (2) and 2 ball
seats (1).
Installing the inlet manifold
Fig. 12: Central body with inlet manifold
Personnel:
Mechanic
Protective equipment:
Eye protection
Protective gloves
Anti-Static Safety Boots
Requirements:
Pump is properly disassembled.
1. Remove 4 screws (4) from outlet manifold (5).
2. Remove outlet manifold (5).
3. Remove 2 balls (1), 2 O-rings (2) and 2 ball
seats (3).
9.3.3 Dismantle material assembly.
Remove material cover and membrane.
Fig. 13: Material cover and membrane
Personnel:
Mechanic
Protective equipment:
Eye protection
Protective gloves
Anti-Static Safety Boots
Requirements:
Inlet and outlet manifold are dismantled.
1. Remove 10 screws (10) and 10 nuts (2) on
material cover (11).
2. Remove material cover (11).
3. Remove membrane screw (12).
Maintenance
01/2020
EcoPump AD - MPU00013EN