Fig. 10: Compressed air connection
Personnel:
Mechanic
Protective equipment:
Eye protection
Protective gloves
Anti-Static Safety Boots
1. Install a filter in the air supply line.
ð
The filter must filter out particles above 50
µm.
2. Connect compressed air hose to the com-
pressed air connection (1).
6
Commissioning
6.1
Safety recommendations
WARNING!
Excessive input pressure
Charging the pump with excessive input pressure
will damage the pump. Serious injuries and death
can be the consequence.
– Charge the pump with low pressure at the
time of commissioning.
– Before increasing the pressure, check that
hoses and connections are seated tightly.
– Increase pressure gradually, until the max-
imum input pressure is reached.
– Do not exceed maximum input pressure.
WARNING!
Sparks due to electrostatic discharge
If the pump is not grounded, there can be an
electrostatic charge on the the pump. Electro-
static discharge can cause sparks that in explo-
sive atmosphere can cause a fire or an explo-
sion. Serious injury and death could be the
consequence.
– Ground Pump as specified.
– Before carrying out any work, make sure that
there is no explosive atmosphere.
WARNING!
Escaping material
Escaping compressed material can cause
serious injury.
Before commissioning:
– Check ball valve for functioning.
WARNING!
Danger from harmful or irritant substances
Serious injuries or death can result if you come
into contact with dangerous fluids or steam.
– Pump Check regularly for leakage. Observe
local regulations and maintenance schedule.
– Ensure that the forced ventilation is opera-
tional.
– Follow the safety data sheet.
– Wear specified protective clothing.
– Avoid contact (e.g. with eyes, skin).
Commissioning
01/2020
EcoPump AD - MPU00013EN
12/36