10
Faults
10.1
Defects table
Fault description
Cause
Remedy
Pump not working despite com-
pressed air supply.
Blocked muffler.
Clean and check; replace if required.
12.7 “Operating and auxiliary mate-
Main valve blocked or
soiled.
Clean and check; replace if required.
12.7 “Operating and auxiliary mate-
Pressure line closed.
Open shut-off valve.
Counter pressure too high
Check line and material.
Ball stuck to ball seat.
Check pump before standstill.
Air motor sealing rings
swollen.
Replace sealing rings
Check ambient temperature
Assembly position of the
pump wrong
Install the pump in an upright position.
Pump blows air out of muffler.
Main valve seals worn out
Replace.
Changeover valve seals
worn out.
Replace.
D-valve and ceramic plate
worn out.
Replace.
Changeover valve worn out.
Replace.
No displacement volume
Pump sucks air.
Seal suction line.
Suction valve closed.
Open suction valve.
Volume flow rate exceeded,
Check suction capacity.
Ball and ball seat on suction
side worn out.
Replace.
9.3.2 “Dismantle inlet and outlet
Foreign body between ball
and ball seat
Cleaning
12.7 “Operating and auxiliary mate-
Low displacement volume
Blocked muffler.
Clean and check; replace if required.
Faults
01/2020
EcoPump AD - MPU00013EN
23/36