Fault description
Cause
Correction
Nozzle soiled or defective
Clean and check the nozzle. If nozzle
is defective, replace it along with the
Air leaks from the mate-
rial flow control
Piston sleeve worn out
Replace piston sleeve
Air leak from the
leakage bore
O-rings of the piston worn
out
Replace O-rings
Sealing rings worn out
Have the sealing rings replaced by
Dürr Systems.
Air leak between piston
axis and housing
Lip seal worn out
Have the lip seal replaced by Dürr
Systems.
Or replace lip seal with assembly /
disassembly tool for lip seal (
Uneven spray jet
Nozzle soiled or defective
Clean and check the nozzle. If nozzle
is defective, replace it along with the
Material pressure too low.
Increase material pressure.
Infeed line pinched or
broken
Check infeed line.
Needle does not open.
Check Control air.
Check operation of needle. Replace
needle, if defective, together with the
nozzle
Cap nut or nozzle is not
properly tightened
Tighten cap nut and nozzle
Needle seal worn out
Replace needle seal
Formation of large drops Delay time too short