4.3
Setting the spray jet
Personnel:
Operator
+ additional qualification explosion pro-
tection
Protective equipment:
Protective workwear
Protective gloves
Fig. 6: Adjust spray jet
The orientation of the spray jet can be
changed to any direction by rotating the air
cap (2).
1. Lightly loosen the cap nut (1).
Fig. 7: Align air cap
2. Rotate air cap (2) into the required posi-
tion.
3. Hand-tighten cap nut (1).
5
Commissioning
Personnel:
Operator
+ additional qualification explosion pro-
tection
Protective equipment:
Use ear protection
Eye protection
Respiratory protection device
Protective workwear
Protective gloves
Depending on the design of the application
system, two technicians must be present to
execute the commissioning:
Technician 1: Operates the controls.
Technician 2: Check on the spray gun.
1. Actuate the spray gun without material
via the control unit or the visualizer.
2. Check the switching behavior.
Does the needle open and close as
required?
Are all types of air supply connected?
4. Connect material.
5. Create a trial spray pattern on a test work
piece.
Commissioning
02/2020
EcoGun AS AUTO pro HD - MSG00009EN
11/44