![Dormakaba Saflok RT Installation Instructions Manual Download Page 12](http://html.mh-extra.com/html/dormakaba/saflok-rt/saflok-rt_installation-instructions-manual_2522830012.webp)
12
Saflok RT/RT Plus Installation Guide PK3720_T 04-19
C
3.5
Reversing the Outside Lever
(for series without Mechanical Override)
The lever is field reversible. If the handing is incorrect, insert a
small pick or flat screwdriver in the hole in the hub as shown.
Gently pry back the spring clip inside the hub, and remove the
handle.
Access Hole
cut-away view
CAUTION
WARNING
IMPORTANT
If the lock makes a continuous buzzing noise or the red LED
lights continuously, reset the electronics by removing the
battery holder for ten seconds then reinsert it.
For models 79Z, 79Y, 79Q connect the outside housing an-
tenna cable (X) to the inside trim antenna cable (W). For the
79R model leave the outside housing antenna cable (X) in the
door hole.
CAUTION
WARNING
IMPORTANT
Ensure no cables are pinched on assembly.
Fasten to the outside housing using the three 1/8" hex drive
mounting screws (I ). Install the screws without tightening.
Verify the inside lever and thumbturn operates smoothly. If
not move the inside and outside housings slightly. Then tight-
en the screws.
S
G
F
X
W
T
I
I
I
S
8. Assemble the lever on the outside housing, in the horizon-
tal rest position appropriate to the handing of the door.
Simply push the lever onto the tube until it clicks in place.
If more force is required, use a rubber mallet. Test the at-
tachment of the handle by pulling smartly on it. (For locks
with mechanical override, see section 4 p.12)
9. Three AA Alkaline batteries should already be installed in
the battery holder (C). Insert the battery holder into the
outside housing and secure it using the 6-32 x 5/16" (7.9mm)
Torx drive screw (H).
3 Installation of Standard ASM or ESM Models
(for cylindrical see Appendix B)